HEAT VALVE [44 records]

Record 1 2017-05-31

English

Subject field(s)
  • Fire Detection
  • Fire-Fighting and Rescue Equipment
  • Fixed Rescue Facilities (fire)
DEF

A dry sprinkler system in which automatic devices charge the pipes before the individual heads open and begin to discharge the extinguishing agent.

CONT

Pre-action Systems : Pre-action systems are dry-pipe systems in which the air in the piping may or may not be under pressure. When a fire occurs, a supplementary fire detecting device in the protected area is actuated. This opens a valve which permits water to flow into the piping system before a sprinkler is activated. Then there is no further delay when a sprinkler is subsequently opened by the heat of the fire.

OBS

preaction sprinkler system; preaction system: terms officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Détection des incendies
  • Matériel de secours et de lutte (incendies)
  • Installations fixes de secours (incendies)
DEF

Système composé d'extincteurs automatiques fixés à un réseau de tuyauterie contenant de l'air pouvant ou non être sous pression, et muni d'une installation de détection d'incendie située dans les mêmes zones que les extincteurs automatiques; le déclenchement du système de détection, causé par un incendie, ouvre un robinet qui permet à l'eau de pénétrer dans tout le réseau de tuyauterie et de couler par les extincteurs automatiques qui sont ouverts.

OBS

système d'extincteurs automatiques à préaction; système à préaction : termes uniformisés par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 1

Record 2 2016-05-24

English

Subject field(s)
  • Fueling Systems (Motor Vehicles)
CONT

The intake-manifold heat control system should pass hot air through, or against, the intake manifold only when the engine is cold. When the engine is warm, the hot exhaust gases should not contact the intake manifold. The valve that takes care of this job is often called the heat-riser valve.

French

Domaine(s)
  • Alimentation (Véhicules automobiles)
CONT

Pour améliorer la vaporisation du carburant (pendant le réchauffage du moteur) on utilise un dispositif pour réchauffer la tubulure d'admission [...] appelé volet de réchauffeur [...]

Spanish

Save record 2

Record 3 2014-11-20

English

Subject field(s)
  • Fixed Rescue Facilities (fire)
  • Fire Prevention
CONT

fusible link : a connective link device used to permit operation of fire protection device when heat causes the fusible link or element to melt releasing a weight or valve.

French

Domaine(s)
  • Installations fixes de secours (incendies)
  • Prévention des incendies
CONT

fusible link: dispositif dont la rupture, sous l'effet d'une chaleur anormale, assure la mise en œuvre de moyen de secours contre l'incendie : fermeture de portes coupe-feu, ouverture de vannes ou de têtes d'extincteurs automatiques.

Spanish

Save record 3

Record 4 2014-08-22

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Nuclear Fission Reactors
DEF

A valve in the piping that penetrates the reactor containment, whose purpose is to shut off the containment system from the said piping.

CONT

Systems directly connected to [the] heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

OBS

isolation valve: term and definition standardized by ISO in 1997.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Réacteurs nucléaires de fission
DEF

Vanne sur la tuyauterie traversant l'enceinte de confinement d'un réacteur, dont le rôle est d'isoler le système de confinement de ladite tuyauterie.

CONT

Les systèmes directement liés au circuit caloporteur qui peuvent être ouverts en cours d'exploitation normale de la centrale, doivent être munis des mêmes dispositifs d'isolement que tout système normalement fermé, si ce n'est que l'on ne doit pas utiliser de vannes manuelles à l'intérieur de l'enceinte. Il faut que l'une des deux vannes d'isolement au moins soit automatique (un clapet par exemple) ou actionnée depuis la salle de commande.

OBS

vanne d'isolement : terme et définition normalisés par l'ISO en 1997.

Spanish

Save record 4

Record 5 2011-12-12

English

Subject field(s)
  • Nuclear Plant Safety
  • Nuclear Fission Reactors
CONT

Trips employing auxiliary trip units include the Loss of Load trip and the APD – High trip. The Loss of Load trip is a contact input from the Electro Hydraulic Control System control oil pressure on each of the four high pressure stop valves. … 10. Loss of Load. The Loss of Load(turbine stop valve(TSV) control oil pressure) trip is anticipatory for the loss of heat removal capabilities of the secondary system following a turbine trip. The Loss of Load trip prevents lifting the pressurizer saftey valves, PORVs and MSSVs in the event of a turbine generator trip. Thus, the trip minimizes the pressure and temperature transients on the reactor by initiating a trip well before reaching the Pressurizer Pressure – High trip and pressurizer safety valve setpoints. The four RPS Loss of Load reactor trip channels receive their input from sensors mounted on the high pressure TSV actuators. Since there are four high pressure TSVs, one actuator per valve and one sensor per actuator, each sensor sends its signal to a different RPS channel. When the turbine trips, control oil is dumped from the high pressure TSVs. When the control oil pressure drops to the appropriate setpoint, a reactor trip signal is generated.

French

Domaine(s)
  • Sûreté des centrales nucléaires
  • Réacteurs nucléaires de fission
DEF

Ensemble constitué d’appareils de mesure, de systèmes de conditionnement et de traitement des signaux de systèmes, de préparation et d’émission des ordres et d’actionneurs permettant de déclencher l’arrêt d’urgence d’un réacteur nucléaire.

Spanish

Save record 5

Record 6 2011-11-22

English

Subject field(s)
  • Water Heaters and Softeners (Household)
CONT

Gas-fired water heaters have a gas burner located below the tank, a thermostatic switch, a gas valve and a pilot light. The thermostat will open the gas valve when it senses the water temperature at the bottom of the tank has dropped below the present limit. Gas flows to the burner and is ignited by the pilot light, heating the tank from below. In addition, the hot exhaust gases are vented through a hollow core in the center of the tank to help heat the water. The exhaust is then passed into the draft hood and to the vent connector where it is discharged to a chimney flue.

OBS

gas water heater: term officially approved by the Lexicon Project Committee (New Brunswick).

Key term(s)
  • gas fired water heater

French

Domaine(s)
  • Chauffe-eau et adoucisseurs d'eau
CONT

Il existe cinq types de chauffe-eau domestiques : le chauffe-eau selon la demande (sans réservoir), le chauffe-eau intégré au système de chauffage, le chauffe-eau à réservoir de stockage, le chauffe-eau à thermopompe et le chauffe-eau solaire. [...] Il existe quatre modèles de chauffe-eau à réservoir de stockage : électrique, au mazout, au gaz naturel et au gaz propane.[...] Chauffe-eau utilisant une source d’énergie fossile. Les sources d’énergie fossile (mazout, gaz naturel ou propane liquide) nécessitent un dispositif d’évacuation, soit une cheminée ou un conduit dans un mur extérieur. Pour des appareils équivalents, les coûts d’opération des chauffe-eau au gaz ou au mazout sont habituellement moins élevés que les chauffe-eau électriques, tout dépendant des prix en vigueur..

OBS

chauffe-eau au gaz : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 6

Record 7 2011-10-24

English

Subject field(s)
  • Security Devices
  • Fire Warning Devices
CONT

Emergency Electronic Bell Tone System(Alert/Alarm Signal). An emergency electronic alert/alarm bell tone is broadcast over the public address system located throughout the building. Upon activation of a smoke detector, heat detector, water sprinkler flow valve, a manual pull station or the deliberate intervention of the operators within the Building Fire/Safety Control Centre, the electronic bell tone will sound warning occupants of a possible emergency. The bell tone indicates an ALERT or ALARM condition.

French

Domaine(s)
  • Dispositifs de sécurité
  • Alarme-incendie
CONT

Les haut-parleurs de l'édifice diffusent également une sonnerie électronique d'alarme ou d'alerte. Dès qu'un détecteur de fumée ou de chaleur est activé, qu'une valve de tête d'extincteur est ouverte, qu'une alarme est manuellement actionnée ou que les opérateurs du Centre de contrôle de l'édifice interviennent volontairement, la sonnerie électronique se déclenche pour avertir les occupants d'une éventuelle situation d'urgence. Le rythme de la sonnerie indique s'il s'agit d'une ALERTE ou d'une ALARME ».

Spanish

Save record 7

Record 8 - external organization data 2011-02-10

English

Subject field(s)
  • Translation (General)
  • Nuclear Plant Safety
  • Compartment - Canadian Nuclear Safety Commission
CONT

The moderator D2O collection system collects moderator water from known leak points. These typically include pump seals, gaskets, and packing around valve stems. The collection system also accepts drainage from vent lines, from heat exchangers and from pumps.

French

Domaine(s)
  • Traduction (Généralités)
  • Sûreté des centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Le circuit de collecte du modérateur (D2O) recueille le modérateur aux points de fuite connus. Ceux-ci comprennent habituellement les joints de pompe, les garnitures et l'habillage des tiges des vannes. Le circuit de collecte recueille également le drainage provenant des conduits d'éventage, des échangeurs de chaleur et des pompes.

Spanish

Save record 8

Record 9 2010-02-09

English

Subject field(s)
  • Fixed Rescue Facilities (fire)
CONT

A fire sprinkler system shall be provided that will automatically shut-off the water supply flow control valve when the fires heat source has been controlled and a soak timer has expired. If the fires heat source was to regenerate, the fire sprinkler system shall automatically reopen. This cycling feature of the sprinkler system shall not be dependent on manual supervision. Cycling fire sprinkler system shall be a closed head type of preaction system with a supplemental detection system which will activate flow control valve.

CONT

Cycling sprinkler. A development by the sprinkler industry is a sprinkler that cycles on and off as needed.... Under normal conditions, the pilot valve is held closed by the snap disc. Water in the piston chamber holds the piston closed. When the snap disc is heated to the rated temperature, it opens the pilot valve and releases the water from the piston chamber. This allows the piston to open and water to flow from the sprinkler. When the snap disc cools to approximately 100°F, it closes the pilot valve.

OBS

"Flow Control" sprinklers are a product of Central Sprinkler Corporation.

Key term(s)
  • cycling type sprinkler
  • cycling type fire sprinkler

French

Domaine(s)
  • Installations fixes de secours (incendies)
CONT

Sprinkleurs spéciaux [...] sprinkleurs «on/off» dont l'obturateur peut s'ouvrir et se refermer suivant la température sous l'action d'un bilame, utiles pour réduire l'arrosage au minimum.

Spanish

Save record 9

Record 10 2009-10-27

English

Subject field(s)
  • Pumps
  • Nuclear Fission Reactors
CONT

The reactor auxiliary building... also houses the long-term cooling(LTC) pumps and heat exchangers, the spent fuel bay cooling and purification system pumps and heat exchangers, the essential cooling water pumps, heat exchangers and valve stations, and the essential service water valve stations.

Key term(s)
  • long term cooling pump

French

Domaine(s)
  • Pompes
  • Réacteurs nucléaires de fission
CONT

Le bâtiment de réacteur auxiliaire [...] abrite les pompes et échangeurs de chaleur de refroidissement à long terme (LTC), les pompes et échangeurs de chaleur du système d'épuration et de refroidissement de la piscine de refroidissement du combustible irradié, les pompes, échangeurs de chaleur et stations de robinetterie d'eau de refroidissement essentiels ainsi que les stations de robinetterie d'eau de refroidissement.

Spanish

Save record 10

Record 11 2009-10-07

English

Subject field(s)
  • Mechanical Components
  • Nuclear Fission Reactors
CONT

The cooling water filling the reactor vessel, heated by the core, gets hotter and its pressure rises. A relief valve at the top of the pressurizer tank-the so-called pilot-operated relief valve(PORV)-opens automatically, steam escapes. But the temperature and pressure of the water in the primary system continue to rise because heat generated by uranium fission in the reactor's core is no longer being removed from the reactor cooling water in the steam generator.

Key term(s)
  • pilot operated relief valve

French

Domaine(s)
  • Composants mécaniques
  • Réacteurs nucléaires de fission
CONT

[La centrale Three Mile Island-2 et sa conception] Le pressuriseur du circuit primaire était placé sur la branche chaude de la boucle A; une vanne de décharge électropneumatique (PORV : Pilot-Operated Relief Valve) était installée dans la partie supérieure du pressuriseur. Cette conception des GV [générateurs de vapeur] entraînait un inventaire en eau du circuit primaire notablement inférieur à celui des réacteurs ayant des échangeurs de chaleur à tubes en U (cas des réacteurs REP [réacteurs à eau pressurisée] français), et rendait donc le réacteur un peu plus sensible aux transitoires.

Spanish

Save record 11

Record 12 - external organization data 2008-11-19

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Systems directly connected to heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire

Spanish

Campo(s) temático(s)
  • Obturadores y boquillas (Componentes mecánicos)
  • Tuberías y accesorios
  • Centrales nucleares
  • Compartimiento - Comisión Canadiense de Seguridad Nuclear
Save record 12

Record 13 2008-04-01

English

Subject field(s)
  • Aircraft Systems
CONT

Leaks... fall into two basic types : internal leakage [such] as a thin oil film is built into the working parts of a hydraulic system. This lubricates the mating surfaces of valve spools, cylinder pistons, and other moving parts. Oil is not lost through this normal internal leakage since it eventually returns to the system reservoir. However, too much internal leakage will slow the operation of the system and waste power through the generation of heat. In some cases, it may cause cylinders to creep or drift. Or it may cause loss of oil control in the valves.... External oil leaks not only look bad-they can be expensive and hazardous.... A small leak can also be the signal for a hydraulic rupture that may injure a person while putting the machine out of operation.... Every joint in a hydraulic circuit is a potential point of leakage. This is why the number of connections in a system is kept at a minimum. Components can leak, but care in assembly and use of new seals and gaskets during overhaul will help to reduce this problem.

PHR

Fluid, zero leakage.

PHR

Oil leak.

PHR

External, fluid, hydraulic, internal leakage.

PHR

Permanent leak.

French

Domaine(s)
  • Circuits des aéronefs
CONT

Les fuites [...] peuvent être classées en deux groupes fondamentaux. Les fuites internes [...] telles que les minces films d'huile se créent dans les pièces en mouvement d'un système hydraulique, ceux-ci lubrifiant les surfaces d'usure des tiroirs de distributeurs, les pistons de vérins et toutes les autres pièces en mouvement. Ces fuites internes, normales, n'entraînent pas de pertes d'huile, celle-ci peut éventuellement retourner au réservoir du système. Toutefois, des fuites internes trop importantes ralentissent le fonctionnement du système et l'échauffement entraîne une perte de puissance. Dans certains cas, les vérins peuvent glisser ou flotter ou il peut y avoir diminution de l'action de l'huile dans les distributeurs. [...] Non seulement les fuites externes ne sont pas esthétiques, mais elles sont aussi onéreuses et présentent des risques. [...] Chaque joint d'un circuit hydraulique est un point de fuite en puissance. C'est pourquoi il y a le moins de raccords possible dans un système. Certains composants peuvent fuire, mais le soin apporté à leur assemblage et l'utilisation de joints neufs peuvent aider à diminuer l'importance de ce problème.

PHR

Fuite de fluide, de liquide, d'huile.

PHR

Fuite externe, hydraulique, interne, permanente.

Spanish

Save record 13

Record 14 - external organization data 2006-11-27

English

Subject field(s)
  • Mechanical Components
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

The moderator D2O collection system collects moderator water from known leak points. These typically include pump seals, gaskets, and packing around valve stems. The collection system also accepts drainage from vent lines, from heat exchangers and from pumps.

French

Domaine(s)
  • Composants mécaniques
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Le circuit de collecte du modérateur (D2O) recueille le modérateur aux points de fuite connus. Ceux-ci comprennent habituellement les joints de pompe, les garnitures et l'habillage des tiges des vannes. Le circuit de collecte recueille également le drainage provenant des conduits d'éventage, des échangeurs de chaleur et des pompes.

Spanish

Save record 14

Record 15 2001-11-02

English

Subject field(s)
  • Orbital Stations
CONT

The Common Cabin Air Assembly(CCAA) in the U. S. On-Orbit Segment modules of ISS provides the capability to control the cabin air temperature, maintain the cabin air humidity level within limits, and generate ventilation air flow. The CCAA includes orbital replaceable unit(ORU) subassemblies for the fan, condensing heat exchanger, water/gas separator, liquid & temperature sensor, temperature control valve, and an electronics box. The Common Cabin Air Assembly is used in four U. S. modules : Hab, Lab, Node 2, and Airlock.

OBS

common cabin air assembly; CCAA: term and abbreviation officially approved by the International Space Station official approval Group (ISSOAG).

French

Domaine(s)
  • Stations orbitales
OBS

La Station spatiale internationale est encore embryonnaire et ne peut accueillir que 3 à 7 personnes. La gestion de l'air y tient un rôle primordial. Les ingénieurs de la NASA ont donc porté une attention toute particulière au système qui doit non seulement fournir l'oxygène et retirer le gaz carbonique de l'atmosphère de la cabine, mais également éviter l'accumulation d'autres gaz comme l'ammoniac et l'acétone produits en petites quantités par le corps humain.

OBS

système de gestion de l'air des modules américains; CCAA : terme et abréviation uniformisés par le Groupe de travail de la terminologie de la Station spatiale internationale (GTTSSI).

Spanish

Save record 15

Record 16 2000-06-30

English

Subject field(s)
  • Air Conditioning and Heating
DEF

That quantity or condition of a controlled medium which is measured and controlled. For example, temperature, pressure, flow rate, volume, level, or concentration.

CONT

The room thermostat is placed so that it measures temperature(controlled variable) in the room air(controlled medium), and operates a valve which regulates the flow(manipulated variable) of the steam(control agent) through the heating coil. Heat from the coil is thus furnished to the room air.

French

Domaine(s)
  • Conditionnement de l'air et chauffage

Spanish

Save record 16

Record 17 2000-06-20

English

Subject field(s)
  • Air Conditioning and Heating
DEF

That quantity or condition which is regulated by the automatic control system in such a manner that it causes the desired change in the controlled variable. The manipulated variable is a characteristic of the control agent.

CONT

The room thermostat is placed so that it measures temperature(controlled variable) in the room air(controlled medium), and operates a valve which regulates the flow(manipulated variable) of the steam(control agent) through the heating coil. Heat from the coil is thus furnished to the room air.

French

Domaine(s)
  • Conditionnement de l'air et chauffage

Spanish

Save record 17

Record 18 2000-06-20

English

Subject field(s)
  • Air Conditioning and Heating
DEF

The substance (usually air, water, or steam) whose characteristics (such as temperature, pressure, flow rate, volume, level, or concentration) are being controlled.

CONT

The room thermostat is placed so that it measures temperature(controlled variable) in the room air(controlled medium), and operates a valve which regulates the flow(manipulated variable) of the steam(control agent) through the heating coil. Heat from the coil is thus furnished to the room air.

French

Domaine(s)
  • Conditionnement de l'air et chauffage

Spanish

Save record 18

Record 19 2000-05-25

English

Subject field(s)
  • Thermodynamics
  • Heating
DEF

The medium which is manipulated by the control system to cause a change in the control medium.

CONT

... suppose a heating coil through which steam is flowing is used to heat a room. The room thermostat is placed so that it measures temperature(controlled variable) in the room air(controlled medium), and operates a valve which regulates the flow(manipulated variable) of the steam(control agent) through the heating coil. Heat from the coil is thus furnished to the room air.

French

Domaine(s)
  • Thermodynamique
  • Chauffage
CONT

fluide énergétique. Sous ce vocable, on réunit la force motrice et même l'éclairage, la vapeur et tout autre moyen de chauffage [...] l'eau de refroidissement, le gaz neutre, l'air comprimé, etc.

Spanish

Save record 19

Record 20 1999-10-12

English

Subject field(s)
  • Steam-Powered Machines and Condensers
  • Closing Devices and Nozzles (Mechanical Components)
DEF

A valve at the junction of four waterways which allows passage between any two adjacent waterways by means of a movable element operated by a quarter turn.

CONT

Some [heat pump] units use a four-way valve to reverse the flow of refrigerant. It is operated by the movement of one valve stem which closes and opens several parts in one valve body, either by moving the stem manually or electrically. The complete system is easily reversed with one of these valves. This type valve is popular in small tonnage units such as window units and other air-to-air units.

French

Domaine(s)
  • Machines à vapeur et condenseurs
  • Obturateurs et buses (Composants mécaniques)
CONT

Ces pompes [à chaleur réversibles] comportent, sur le refoulement et sur l'aspiration du compresseur, une vanne à 4 voies qui permet alors d'utiliser le compresseur: - soit aspirant sur l'évaporateur, et la PAC peut alors climatiser et refroidir en été les locaux à traiter (...) - soit aspirant sur le condenseur, celui-ci se transformant alors en évaporateur (...) et on obtient ainsi le chauffage d'hiver des locaux traités par la pompe à chaleur.

Key term(s)
  • vanne à quatre voies

Spanish

Save record 20

Record 21 1998-12-07

English

Subject field(s)
  • Aeronautical Engineering and Maintenance
  • Pipes and Fittings

French

Domaine(s)
  • Aérotechnique et maintenance
  • Tuyauterie et raccords
OBS

Terme extrait du Lexique du CF-18 de Canadair.

Spanish

Save record 21

Record 22 1998-10-29

English

Subject field(s)
  • Pumps
  • Refrigeration Engineering
CONT

The great majority of heat pumps work on the principle of the vapour compression cycle. The main components in such a heat pump system are the compressor, the expansion valve and two heat exchangers referred to as evaporator and condenser. The components are connected to form a closed circuit... A volatile liquid, known as the working fluid or refrigerant, circulates through the four components. In the evaporator the temperature of the liquid working fluid is kept lower than the temperature of the heat source, causing heat to flow from the heat source to the liquid, and the working fluid evaporates. Vapour from the evaporator is compressed to a higher pressure and temperature. The hot vapour then enters the condenser, where it condenses and gives off useful heat. Finally, the high-pressure working fluid is expanded to the evaporator pressure and temperature in the expansion valve. The working fluid is returned to its original state and once again enters the evaporator. The compressor is usually driven by an electric motor and sometimes by a combustion engine.

French

Domaine(s)
  • Pompes
  • Techniques du froid

Spanish

Save record 22

Record 23 1998-07-20

English

Subject field(s)
  • Flight Instruments and Equipment (Aeroindustry)

French

Domaine(s)
  • Instruments et équipement de bord (Constructions aéronautiques)
OBS

Terme et équivalent extraits du Lexique du CF-18 de Canadair.

Spanish

Save record 23

Record 24 - external organization data 1994-10-18

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Systems directly connected to heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Les systèmes directement liés au circuit caloporteur qui peuvent être ouverts en cours d'exploitation normale de la centrale, doivent être munis des mêmes dispositifs d'isolement que tout système normalement fermé, si ce n'est que l'on ne doit pas utiliser de vannes manuelles à l'intérieur de l'enceinte. Il faut que l'une des deux vannes d'isolement au moins soit automatique (un clapet par exemple) ou actionnée depuis la salle de commande.

Spanish

Save record 24

Record 25 - external organization data 1994-10-18

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Systems directly connected to heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Les systèmes directement liés au circuit caloporteur qui peuvent être ouverts en cours d'exploitation normale de la centrale, doivent être munis des mêmes dispositifs d'isolement que tout système normalement fermé, si ce n'est que l'on ne doit pas utiliser de vannes manuelles à l'intérieur de l'enceinte. Il faut que l'une des deux vannes d'isolement au moins soit automatique (un clapet par exemple) ou actionnée depuis la salle de commande.

Spanish

Save record 25

Record 26 - external organization data 1994-10-18

English

Subject field(s)
  • Pipes and Fittings
  • Nuclear Science and Technology
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Small Lines. For ductile piping of small bore, crimping of the pipe is a possible means of providing an isolation barrier instead of a valve.... In the case of primary heat transport system instrument lines, the following extra conditions are required :... the relevant release limits must be shown not to be exceeded during the period in which the reactor is shut down consequent to the failure, and the crimping is executed....

French

Domaine(s)
  • Tuyauterie et raccords
  • Sciences et techniques nucléaires
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Petites canalisations. Pour les canalisations ductiles de faible calibre, le fait de les aplatir peut tenir lieu de barrière d'isolement à la place d'une vanne. [...] Dans le cas des canalisations reliées aux appareils de mesure du circuit caloporteur primaire, les conditions supplémentaires suivantes doivent être remplies : [...] les mesures de rejet ne doivent pas dépasser les limites pertinentes au cours de la période pendant laquelle le réacteur est neutralisé après une défaillance, et que l'aplatissement est effectué [...]

Spanish

Save record 26

Record 27 1992-02-26

English

Subject field(s)
  • Packaging in Plastic
DEF

Gusseted tube closed at both ends by means of continuous transverse heat sealing provided with a side valve.

OBS

Term standardized by ISO.

French

Domaine(s)
  • Emballages en matières plastiques
DEF

Tube à soufflets fermé aux deux extrémités par soudage transversal continu, muni d'une valve latérale.

OBS

Terme normalisé par l'ISO.

Spanish

Save record 27

Record 28 1992-02-26

English

Subject field(s)
  • Packaging in Plastic
DEF

Flat tube closed at one end by means of continuous transverse heat sealing and at the other end, which includes the valve, by folding, forming and pasting in a hexagonal shape.

OBS

Term standardized by ISO.

French

Domaine(s)
  • Emballages en matières plastiques
DEF

Tube plat fermé à une extrémité par soudage transversal continu et à l'autre extrémité, celle comportant la valve, par pliage, façonnage et collage en forme hexagonale.

OBS

Terme normalisé par l'ISO.

Spanish

Save record 28

Record 29 1992-02-26

English

Subject field(s)
  • Packaging in Plastic
DEF

Flat tube closed at both ends by means of continuous transverse heat sealing provided with a side valve.

OBS

Term standardized by ISO.

French

Domaine(s)
  • Emballages en matières plastiques
DEF

Tube plat fermé aux deux extrémités par soudage transversal continu, muni d'une valve latérale.

OBS

Terme normalisé par l'ISO.

Spanish

Save record 29

Record 30 1992-02-26

English

Subject field(s)
  • Packaging in Plastic
DEF

One corner of a tube is folded in, thus creating a valve after heat sealing.

OBS

Term standardized by ISO.

French

Domaine(s)
  • Emballages en matières plastiques
DEF

Un coin du tube est replié à l'intérieur, créant ainsi une valve après soudage.

OBS

Terme normalisé par l'ISO.

Spanish

Save record 30

Record 31 1991-02-28

English

Subject field(s)
  • Machinery
CONT

Closed centre-all ports are blocked off in neutral. The cylinder is "locked" and the piston will stay in position-over a period of time the piston will drift, due to minor internal leaks. The fluid from the pump will go through the relief valve at maximum pressure, generating heat and requiring maximum hp.

French

Domaine(s)
  • Machines
CONT

Centre fermé. Il bloque entièrement un récepteur en n'importe quelle position par verrouillage hydraulique sur les deux chambres. Il bloque aussi le débit de la pompe, ce qui permet son utilisation pour un autre circuit.

Spanish

Save record 31

Record 32 1990-04-30

English

Subject field(s)
  • Aeronautical Engineering and Maintenance
  • Aircraft Interiors
  • Aircraft Systems

French

Domaine(s)
  • Aérotechnique et maintenance
  • Aménagement intérieur des aéronefs
  • Circuits des aéronefs

Spanish

Save record 32

Record 33 1989-12-15

English

Subject field(s)
  • Aeroindustry

French

Domaine(s)
  • Constructions aéronautiques
OBS

Termes tirés du Lexique de la section technique, par M. Thibodeau.

Spanish

Save record 33

Record 34 1987-10-01

English

Subject field(s)
  • Reconstituted-Wood Products
  • Wood Drying
OBS

In special cases [air suspension] sifters have also been used as dryers, where a heat source is connected to the air inlet; thus, drying of the furnish takes places simultaneously with the sifting. The furnish to be separated falls through a rotary valve and a central feed pipe into the suspension chamber. Rotating stirring arms above the screen floor distribute the material evenly over the area of the screen, through which the airstream enters the suspension chamber from below. With appropriate air velocities, any desired separation of the furnish can be obtained.

OBS

air-classifier: A machine that uses airstream to separate particles on the bases of weight and surface area.

French

Domaine(s)
  • Bois reconstitués
  • Séchage du bois

Spanish

Save record 34

Record 35 1987-05-04

English

Subject field(s)
  • Aeroindustry
CONT

The [freeze prevention] system is located in the aft accessory compartment and consists of a temperature control(modulating and shut-off) valve, temperature control thermostat, mufflers, and ducts. The ground operated APU is used with the left-hand pack to provide the warm air required to raise the temperature of the heat exchanger cooling air. The system taps into the APU bleed air supply duct before the check valve at the elbow under the catwalk and air is distributed by auxiliary ducts to a muffler under the flow control valve of each pack and to a single spray bar upstream of the left diverter valve. A temperature control valve in the ducting regulates the volume of bleed air to be used.

French

Domaine(s)
  • Constructions aéronautiques
CONT

Ce silencieux est fixé par vis sur la prise d'air du refroidisseur d'huile. Il est constitué d'une cuvette et d'un couvercle percés de plusieurs orifices qui permettent le passage de l'air de refroidissement. L'insonorisation est assurée par de la laine de verre qui est placée à l'intérieur de la cuvette.

OBS

silencieux : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 35

Record 36 1987-02-10

English

Subject field(s)
  • Aircraft Systems
CONT

The freeze prevention system maintains the air-conditioning system in a freeze free operating condition in cold weather with extremely high humidity on the ground. The system is located in the aft accessory compartment and consists of a temperature control(modulating and shut-off) valve, temperature control thermostat, mufflers, and ducts. The ground operated APU is used with the left-hand pack to provide the warm air required to raise the temperature of the heat exchanger cooling air.

OBS

in water separator.

French

Domaine(s)
  • Circuits des aéronefs
OBS

système antigivrage : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 36

Record 37 1986-04-01

English

Subject field(s)
  • Fueling Systems (Motor Vehicles)
DEF

In the engine, a thermostatically operated valve in the exhaust manifold; diverts heat to the intake manifold to warm it before the engine reaches normal operating temperature.

French

Domaine(s)
  • Alimentation (Véhicules automobiles)

Spanish

Save record 37

Record 38 1985-10-17

English

Subject field(s)
  • Aeroindustry

French

Domaine(s)
  • Constructions aéronautiques

Spanish

Save record 38

Record 39 1982-04-20

English

Subject field(s)
  • Exhaust Systems (Motor Vehicles)
CONT

Vacuum-controlled heat riser valve uses a vacuum actuator to operate valve.

French

Domaine(s)
  • Échappement (Véhicules automobiles)
CONT

(...) le volet est actionné par une membrane à dépression et par une tringle. La dépression agissant sur la membrane est elle même commandée par un thermocontact (...)

Spanish

Save record 39

Record 40 1982-01-25

English

Subject field(s)
  • Fueling Systems (Motor Vehicles)
OBS

Heat to the intake manifold is(...) needed when the manifold is cold(...) In order to supply heat a thermostatic manifold control valve is installed.

French

Domaine(s)
  • Alimentation (Véhicules automobiles)

Spanish

Save record 40

Record 41 1980-04-16

English

Subject field(s)
  • Air Transport

French

Domaine(s)
  • Transport aérien
OBS

terme d'usage obligatoire au Bureau des Traductions.

Spanish

Save record 41

Record 42 1976-06-19

English

Subject field(s)
  • Phraseology
  • Servicing and Maintenance (Motor Vehicles and Bicycles)

French

Domaine(s)
  • Phraséologie
  • Entretien et réparation (Véhicules automobiles et bicyclettes)

Spanish

Save record 42

Record 43 1976-06-19

English

Subject field(s)
  • Machinery
OBS

prév. de superheat

French

Domaine(s)
  • Machines
OBS

machines à vapeur PD 09-09-75

Spanish

Save record 43

Record 44 1975-03-11

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Climate-Control Equipment (Motor Vehicles)
DEF

in the engine, a thermostatically operated valve in the exhaust manifold for varying heat to intake manifold with engine temperature.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Système de conditionnement de l'air (Véhicules automobiles)
CONT

une soupape dite de réchauffage, placée dans la tuyauterie d'échappement fait dévier les gaz chauds dans la chemise lorsqu'elle est ouverte et ferme l'entrée du manchon de réchauffage lorsqu'elle est fermée.

Spanish

Save record 44

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: