TERMIUM Plus®

From: Translation Bureau

On social media

Consult the Government of Canada’s terminology data bank.

INPUT LOAD [35 records]

Record 1 2024-02-22

English

Subject field(s)
  • Vacuum Tubes (Electronics)
  • Amplifiers (Electronics)
DEF

An amplifier in which the output load is in the cathode circuit of an electronic tube and the input is applied between the control grid and the far end of the cathode load.

OBS

cathode follower: term standardized by IEEE.

OBS

cathode follower circuit: term standardized by the International Electrotechnical Commission.

OBS

This type of amplifier has a voltage gain less than unity; it has a high input impedance and a low output impedance; input and output signals are in phase.

OBS

Equivalent transistorized amplifiers are called: emitter follower (pnp and npn transistors) and source follower (FETs).

French

Domaine(s)
  • Tubes et lampes (Électronique)
  • Amplificateurs (Électronique)
DEF

Montage amplificateur dans lequel le signal de sortie est prélevé sur l'impédance cathodique du tube, le signal d'entrée étant appliqué entre la grille de commande et la masse.

OBS

montage à cathode asservie : terme normalisé par la CEI.

OBS

Le montage cathodyne est caractérisé par son impédance d'entrée élevée et sa faible impédance de sortie; les signaux d'entrée et de sortie ne sont pas déphasés et le gain en tension est inférieur à un.

Spanish

Campo(s) temático(s)
  • Tubos de vacío (Electrónica)
  • Amplificadores (Electrónica)
DEF

Tipo de amplificador intermedio o compensador que emplea una válvula termoiónica, en el que el potencial del cátodo "sigue" al de la rejilla.

Save record 1

Record 2 2019-12-19

English

Subject field(s)
  • Computer Programs and Programming
CONT

The batch command reads from standard input the names of commands to be run at a later time and runs the jobs when the system load level permits.

French

Domaine(s)
  • Programmes et programmation (Informatique)
CONT

Une commande par lot est une commande d'utilitaire permettant d'exécuter une liste de commandes [...] à partir d'un fichier texte.

Spanish

Save record 2

Record 3 2017-10-25

English

Subject field(s)
  • Jib-Type Hoisting Apparatus
CONT

Hand hoists are chain operated. There are four types : spur geared, worm geared, differential, and pull-lift or lever... Worm-gear hoists transform about 1/3-l/2 the input energy to useful work. Offsetting this low efficiency is the locking characteristic of the worm drive. The load cannot turn the mechanism; consequently the load is at all times restrained from running away.

Key term(s)
  • worm gear hand hoist
  • worm-geared hand hoist

French

Domaine(s)
  • Appareils de levage à bras
CONT

Les palans à bras. Ils sont de plusieurs sortes. [...] Les palans à vis [...] comprennent une vis sans fin, calée sur un arbre actionné par une noix sur laquelle passe la chaîne de manœuvre. [...] Ces palans sont irréversibles, mais leur faible rendement (0,5) ne permet pas de les utiliser pour des charges supérieures à 5 t. Les [...] palans à vis sont de plus en plus abandonnés au bénéfice des palans à engrenages.

Key term(s)
  • palan à bras à vis sans fin
  • palan à bras à vis

Spanish

Save record 3

Record 4 2016-12-09

English

Subject field(s)
  • Audio Technology
CONT

blocked impedance(transducer). The input impedance of the transducer when its output is connected to a load of infinite impedance... For example, in the case of an electromechanical transducer, the blocked electric impedance is the impedance measured at the electric terminals when the mechanical system is blocked or clamped; the blocked mechanical impedance is measured at the mechanical side when the electric circuit is open-circuited.

French

Domaine(s)
  • Électroacoustique
DEF

Pour un transducteur électromécanique, impédance électrique mesurée à l'entrée lorsque l'impédance mécanique de sortie est infinie : cas de blocage mécanique. [Définition normalisée par l'AFNOR et reproduite avec son autorisation.]

OBS

impédance électrique en blocage mécanique : terme normalisé par l'AFNOR.

Key term(s)
  • impédance électrique en cas de blocage mécanique

Spanish

Save record 4

Record 5 2013-04-03

English

Subject field(s)
  • Air Transport
CONT

Input format requires that a station bumping or moving load must maintain the true desired station and simply add their station as off-load station, which transfers the load to the DPL C display.

French

Domaine(s)
  • Transport aérien
CONT

La séquence d'entrée demande qu'une escale qui commande la débarquement ou le déplacement d'une cargaison maintienne l'escale de destination effective et ajoute simplement son propre indicatif à titre d'escale de déchargement, transformant ainsi la cargaison à l'affichage DPL C.

Spanish

Save record 5

Record 6 2012-03-13

English

Subject field(s)
  • Electrical Engineering
DEF

The voltage which is transferred to the load impedance in a circuit which includes a transductor.

CONT

Output voltage regulation is the change in output voltage, at a specified constant input voltage, resulting from a change of load current between two specified values.

OBS

output voltage: term standardized by the International Electrotechnical Commission (IEC).

French

Domaine(s)
  • Électrotechnique
DEF

Tension appliquée au circuit d'utilisation dans un ensemble comportant un transducteur.

CONT

La tension de sortie de la génératrice est commandée par sa tension d'excitation.

OBS

tension de sortie : terme normalisé par la Commission électrotechnique internationale (CEI) et l'AFNOR.

Spanish

Campo(s) temático(s)
  • Electrotecnia
CONT

La respuesta temporal de la retina de silicio se parece también mucho a la de las células bipolares. Cuando la intensidad de la luz aumenta de repente, existe un gran salto en el voltaje de salida, igual a la diferencia que se aprecia entre la nueva señal de entrada y el voltaje medio almacenado previamente en la red de resistencias .

Save record 6

Record 7 2012-03-06

English

Subject field(s)
  • Office Machinery
  • Computer Programs and Programming
OBS

control card : A punched card that contains input data required for a specific application of a general routine, e. g., to direct an OS(operating system) to load and execute a particular program.

French

Domaine(s)
  • Mécanographie
  • Programmes et programmation (Informatique)
DEF

Carte perforée destinée à commander le système d'exploitation en explicitant le travail de récupération à accomplir.

Spanish

Save record 7

Record 8 2011-12-16

English

Subject field(s)
  • Electronics
  • Electrical Systems
DEF

A device that maintains a voltage source within required limits despite variations in input voltage or load.

French

Domaine(s)
  • Électronique
  • Ensembles électrotechniques
DEF

Régulateur électrique qui maintient la tension entre deux limites suffisamment rapprochées pour qu'elle puisse être considérée comme constante; il permet, en particulier, d'obtenir une tension fixe sur un réseau à tension variable.

Spanish

Campo(s) temático(s)
  • Electrónica
  • Sistemas eléctricos
DEF

Dispositivo o circuito que mantiene un voltaje constante, sin que importen las variaciones de la tensión de entrada o de la carga.

Save record 8

Record 9 2011-12-12

English

Subject field(s)
  • Nuclear Plant Safety
  • Nuclear Fission Reactors
CONT

Trips employing auxiliary trip units include the Loss of Load trip and the APD – High trip. The Loss of Load trip is a contact input from the Electro Hydraulic Control System control oil pressure on each of the four high pressure stop valves. … 10. Loss of Load. The Loss of Load(turbine stop valve(TSV) control oil pressure) trip is anticipatory for the loss of heat removal capabilities of the secondary system following a turbine trip. The Loss of Load trip prevents lifting the pressurizer saftey valves, PORVs and MSSVs in the event of a turbine generator trip. Thus, the trip minimizes the pressure and temperature transients on the reactor by initiating a trip well before reaching the Pressurizer Pressure – High trip and pressurizer safety valve setpoints. The four RPS Loss of Load reactor trip channels receive their input from sensors mounted on the high pressure TSV actuators. Since there are four high pressure TSVs, one actuator per valve and one sensor per actuator, each sensor sends its signal to a different RPS channel. When the turbine trips, control oil is dumped from the high pressure TSVs. When the control oil pressure drops to the appropriate setpoint, a reactor trip signal is generated.

French

Domaine(s)
  • Sûreté des centrales nucléaires
  • Réacteurs nucléaires de fission
DEF

Ensemble constitué d’appareils de mesure, de systèmes de conditionnement et de traitement des signaux de systèmes, de préparation et d’émission des ordres et d’actionneurs permettant de déclencher l’arrêt d’urgence d’un réacteur nucléaire.

Spanish

Save record 9

Record 10 2011-05-19

English

Subject field(s)
  • Cells and Batteries
DEF

A battery operation in which the battery is normally connected to an external current source; for instance, a battery charger which supplies the battery load under normal conditions, while also providing enough energy input to the battery to make up for its internal quiescent losses, thus keeping the battery always up to full power and ready for service.

French

Domaine(s)
  • Piles et accumulateurs
DEF

Opération réalisée sur une batterie qui consiste à relier cette dernière à une source électrique extérieure, notamment un chargeur de batterie, qui fournit la charge de celle-ci dans des conditions normales d'utilisation tout en l'alimentant en énergie pour compenser les pertes internes subies en position de repos, ce qui permet de maintenir sa pleine puissance et sa disponibilité.

Spanish

Save record 10

Record 11 2010-04-19

English

Subject field(s)
  • Electronic Devices
CONT

An integratable driver circuit for driving a power semiconductor, comprising at least one internal amplifier circuit whose output can be connected to an external power semiconductor. In order to limit the switching speed of the output flow, a feedback input which is connected to the input of the amplifier circuit is provided, enabling the load voltage at the output of the power semiconductor to be fed back to the input of the amplifier circuit. A signal limiting circuit is also provided in the feedback branch.

French

Domaine(s)
  • Dispositifs électroniques
CONT

L'invention concerne un circuit d'attaque intégrable servant à exciter un semi-conducteur de puissance et comprenant au moins un circuit amplificateur interne dont la sortie peut être reliée à un semi-conducteur de puissance externe. L'invention vise à limiter la vitesse de commutation du courant de sortie. À cet effet, le circuit selon l'invention comprend une entrée de réinjection qui est reliée à l'entrée du circuit amplificateur et qui sert à réinjecter une tension de charge à la sortie du semi-conducteur de puissance dans l'entrée du circuit amplificateur. Un circuit de limitation de signal est également prévu dans la branche de réinjection.

Spanish

Save record 11

Record 12 2009-10-09

English

Subject field(s)
  • Amplifiers (Electronics)
CONT

An ideal amplifier will pass the input signal through to the output undistorted but enlarged(gain set by user), with no delay. It will not be affected by the output impedance of the source(sensor). In addition the ideal amplifier will be able to drive any load : supply any current.

OBS

ideal amplifier: term standardized by the International Electrotechnical Commission (IEC).

French

Domaine(s)
  • Amplificateurs (Électronique)
OBS

amplificateur idéal : terme normalisé par la Commission électrotechnique internationale (CEI).

Spanish

Save record 12

Record 13 2008-12-02

English

Subject field(s)
  • Audio Technology
  • Measurements of Electricity
DEF

The input impedance of a transducer when its output is connected to a load of infinite impedance.

French

Domaine(s)
  • Électroacoustique
  • Mesures de grandeurs électriques

Spanish

Save record 13

Record 14 2008-05-14

English

Subject field(s)
  • Solar Energy
DEF

The number of consecutive days the stand-alone system will meet a defined load without solar energy input.

OBS

This term is related to system availability.

French

Domaine(s)
  • Énergie solaire
DEF

Nombre de jours consécutifs où un système autonome de production d'énergie satisfait une charge spécifiée sans apport d'énergie solaire.

Spanish

Save record 14

Record 15 2008-05-09

English

Subject field(s)
  • Energy Transformation
  • Solar Energy
DEF

The number of consecutive days the stand-alone system will meet a defined load without solar energy input.

OBS

This term is related to system availability.

French

Domaine(s)
  • Transformation de l'énergie
  • Énergie solaire
DEF

Nombre de jours consécutifs pour lesquels un système photovoltaïque autonome (non relié à un réseau) fournira une charge spécifiée sans recourir à un nouvel apport d'énergie solaire.

Spanish

Save record 15

Record 16 2007-11-28

English

Subject field(s)
  • Banking
  • Loans
CONT

With a prepaid card, you load funds onto your Card and use that money to make purchases and get cash-you are not borrowing money from a bank or other financial institution. The prepaid credit card looks like a credit card-it has the Visa or MasterCard logo and hologram-and allows the convenience of cashless purchases like a signature-based credit card, with no PIN input required at the point-of-sale.

CONT

Pre-paid credit cards are like secured credit cards in that you must deposit your own money to use. However, pre-paid credit cards do not offer a chance to extend you credit like a secured credit card does. Secure credit cards always report to the major credit bureaus where pre-paid credit cards always do not, unless you pay extra.

French

Domaine(s)
  • Banque
  • Prêts et emprunts
CONT

La différence principale entre cartes de crédit sécurisées et cartes de crédit prépayées est que les cartes de crédit sécurisées sont déclarées aux agences d'évaluation du crédit tandis que les cartes de crédit prépayées ne le sont pas.

Spanish

Save record 16

Record 17 2007-07-23

English

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
DEF

A device [in an oil burner] which breaks fuel up into tiny droplets without using an atomizing medium.

CONT

Mechanical Atomizers : In the mechanical atomizer, the pressure of the fuel itself is used as the means for atomization. Mechanical atomizers are available in sizes up to 180 million Btu/hr input, about 10, 000 lb of oil per hr. The acceptable operating range may be as much as ten to one or as little as three to one, depending on the maximum oil pressure used for the system, the furnace configuration, air temperature, and burner throat velocity. Return flow atomizers are ideally suited for standard grades of fuel oil where it is desired to meet load variations without changing sprayer plates or cutting burners in and out of service.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout
CONT

Pulvérisation mécanique à retour. Dans le but d'obtenir une plage de réglage suffisante, le pulvérisateur mécanique est complété d'un circuit de retour qui ramène au réservoir une partie du combustible prélevé dans le pulvérisateur même [...]

CONT

Brûleurs à pulvérisation mécanique de fuel sous pression. Dans ce type de brûleur [...] le fuel est refoulé par l'intermédiaire d'une pompe électrique, à une pression élevée, 7 à 20 bar, dans un gicleur de pulvérisation qui le disperse en un brouillard de fines particules avant vaporisation à haute température [...] C'est le type de brûleur le plus communément utilisé dans les installations de chauffage central.

OBS

pulvérisateur: Lamelle métallique sur laquelle vient se briser avec force un jet d'air et de liquide, qui se pulvérise.

Spanish

Save record 17

Record 18 2004-08-23

English

Subject field(s)
  • Information Processing (Informatics)
DEF

The amount of load imposed upon the sources supplying signals to the input.

French

Domaine(s)
  • Traitement de l'information (Informatique)

Spanish

Campo(s) temático(s)
  • Tratamiento de la información (Informática)
DEF

Carga eléctrica que recae sobre las unidades que proporcionan una señal para la entrada de un dispositivo.

Save record 18

Record 19 2004-07-15

English

Subject field(s)
  • Information Processing (Informatics)
DEF

An error found in computer output caused by a change in the value of the load when input.

French

Domaine(s)
  • Traitement de l'information (Informatique)

Spanish

Campo(s) temático(s)
  • Tratamiento de la información (Informática)
DEF

Error producido en una unidad aritmética o de cálculo (especialmente analógicas) cuando ha existido una variación en el valor cargado inicialmente.

Save record 19

Record 20 2004-04-22

English

Subject field(s)
  • Electrical Networks
  • Telecommunications Transmission
DEF

A form of intervalve coupling in which the inductive output load of one valve is connected through a capacitor to the input circuit of another valve.

French

Domaine(s)
  • Réseaux électriques
  • Transmission (Télécommunications)
DEF

Couplage entre étages dans lequel l'électrode de sortie d'un étage est reliée d'une part à une charge inductive, et d'autre part, à l'électrode d'entrée de l'étage suivant par l'intermédiaire d'un condensateur.

Key term(s)
  • couplage LC

Spanish

Campo(s) temático(s)
  • Redes eléctricas
  • Transmisión (Telecomunicaciones)
Save record 20

Record 21 2004-04-20

English

Subject field(s)
  • Electrical Networks
  • Telecommunications Transmission
  • Electronic Devices
DEF

A form of interstage coupling in which the resistive output load of one stage is connected through a capacitor to the input circuit of another stage.

Key term(s)
  • R/C coupling
  • resistance/capacitance coupling

French

Domaine(s)
  • Réseaux électriques
  • Transmission (Télécommunications)
  • Dispositifs électroniques
DEF

Couplage entre étages dans lequel l'électrode de sortie d'un étage est reliée d'une part à une charge résistive et d'autre part à l'électrode d'entrée de l'étage suivant par l'intermédiaire d'un condensateur.

Key term(s)
  • couplage par résistance/capacité
  • couplage R/C

Spanish

Campo(s) temático(s)
  • Redes eléctricas
  • Transmisión (Telecomunicaciones)
  • Dispositivos electrónicos
Save record 21

Record 22 2002-09-09

English

Subject field(s)
  • Electrical Equipment (Motor Vehicles)
  • Suspension Systems (Motor Vehicles and Bicycles)
DEF

Optical sensor located on the lower part of the vehicle body or on the suspension axles, measuring body height relative to the ground.

CONT

Vehicle trim height is noted by height sensors. They are used to note changes in the load on the vehicle and allow the suspension to compensate for it, maintaining the ideal body height. In addition to noting load changes within the vehicle and compensating for them, some height sensors are used to inform the suspension module of road ondulations(such as railroad tracks). In addition to vehicle height, the module requires input signals to indicate which part of the vehicle needs a height correction. One sensor, located in the front of the rear axle detects load changes in the luggage compartment and passenger rear seats. The remaining two sensors are positioned at each front wheel to detect driver and passenger seat loads.

OBS

An additional height sensor may be located in the wheel arch, measuring body height, but this time relative to the wheel, playing the role of a body displacement sensor.

French

Domaine(s)
  • Équipement électrique (Véhicules automobiles)
  • Suspension (Véhicules automobiles et bicyclettes)
DEF

Capteur optique placé sur la partie inférieure de la carrosserie ou sur les essieux de suspension mesurant la hauteur de la caisse par rapport au sol.

CONT

La hauteur de suspension est mesurée par les capteurs de hauteur. Ces capteurs permettent de déceler les variations de charge, dont la suspension doit tenir compte pour maintenir la hauteur caractéristique de la carosserie. En plus de mesurer les variations de charge du véhicule et de permettre à la suspension de les compenser, certains capteurs de hauteur informent le module de commande des irrégularités de la route (comme c'est le cas lorsque la voiture traverse un passage à niveau). En plus de la hauteur du véhicule, le module exige d'autres signaux pour lui indiquer quelle partie de la voiture exige une correction de hauteur. Un capteur, situé en avant de l'essieu arrière, mesure les variations de charge dans le coffre et au niveau des sièges arrière. Les deux autres capteurs sont situés au niveau de chaque roue avant, pour mesurer la charge supportée par le siège du conducteur et le siège du passager.

OBS

On peut aussi trouver un capteur de hauteur supplémentaire dans le passage de roue, mesurant la hauteur de la caisse, mais par rapport à la roue cette fois, jouant ainsi le rôle d'un capteur de débattement de caisse.

Spanish

Save record 22

Record 23 2001-09-19

English

Subject field(s)
  • Financial and Budgetary Management
  • Government Accounting
CONT

This file must accompany each bulk input file of payments or interdepartmental settlements. It contains the control data for processing the input files, including the requisition information, electronic authorization and authentication(EAA), and client profile data. Each requisition submitted on the generic payment input file or the interdepartmental settlement input file must have a corresponding entry on the auto-load control file. This file triggers the automatic edit and load of the generic payment input file or the generic interdepartmental settlement input file.

Key term(s)
  • auto load client control file
  • auto load control file

French

Domaine(s)
  • Gestion budgétaire et financière
  • Comptabilité publique
CONT

Ce fichier doit accompagner chaque fichier d'entrée des paiements par lots ou les règlements interministériels. Il comprend les données de contrôle pour le traitement des fichiers d'entrée dont : l'information sur les demandes de paiement, l'autorisation et l'authentification électroniques (AAE) et les données sur le profil de client. Chaque demande de paiement soumise avec le fichier générique d'entrée des paiements ou le fichier d'entrée des règlements interministériels, doit correspondre à une écriture dans le fichier de contrôle de l'autochargement. Ce fichier déclenche les fonctions automatiques d'édition et chargement du fichier générique d'entrée des paiements ou du fichier générique d'entrée des règlements interministériels.

Spanish

Save record 23

Record 24 2001-08-28

English

Subject field(s)
  • Financial and Budgetary Management
  • Government Accounting
CONT

Departments can input numerous transactions to the SPS through the use of a Bulk Input File. When IS [interdepartmental settlement] transactions are processed through a Bulk Input File, the initiator submits two files, the SPS [Standard Payment System] generic IS Input file which contains the IS details, and the generic SPS Control file, which contains the high level requisition information including electronic authorization. The control file triggers the autoload process, which initiates the edit and load of the IS details to the SPS system.

French

Domaine(s)
  • Gestion budgétaire et financière
  • Comptabilité publique
CONT

En utilisant le système de saisie globale, les ministères peuvent soumettre plusieurs opérations au SNP [Système normalisé des paiements]. Si la demande de RI [règlement interministériel] est établie dans le cadre de la saisie globale des données, l'émetteur soumet deux fichiers, un fichier de saisie générique de demandes de RI du SNP renfermant les détails sur les RI et un fichier générique de contrôle du SNP contenant l'information à un niveau supérieur portant sur les demandes de RI y compris l'autorisation électronique. Le fichier de contrôle enclenche le processus d'autochargement qui initie la validation et le chargement des détails sur les RI dans le SNP.

CONT

Pour faire une demande de paiement, le ministère client doit transmettre les détails de la transaction (nom, date, montant, adresse de livraison, information pour la transmission des paiements à l'institution financière et, au besoin, détails à reproduire sur le talon du chèque) au SNP [Système normalisé des paiements], sous forme de fichier d'entrée par lot.

Spanish

Save record 24

Record 25 2000-05-25

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
DEF

An automatic control valve for regulating the input to a burner in response to a load demand.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
OBS

régulateur. Dispositif de correction automatique d'un niveau d'eau, d'un débit, d'une pression, d'une température, d'une vitesse de rotation, d'une tension électrique, etc.

Spanish

Save record 25

Record 26 1999-05-06

English

Subject field(s)
  • Office Machinery
OBS

control card : A punched card that contains input data required for a specific application of a general routine, e. g., to direct an OS to load and execute a particular program.

French

Domaine(s)
  • Mécanographie

Spanish

Save record 26

Record 27 1998-09-16

English

Subject field(s)
  • Mechanical Transmission Systems
DEF

Change in load pressure drop per unit input signal with zero control flow(control ports blocked).

French

Domaine(s)
  • Transmissions mécaniques
DEF

Variation par unité du signal d'entrée, de la chute de pression due à la charge, avec un débit modulé nul (orifice d'utilisation obturé).

Spanish

Save record 27

Record 28 1996-08-19

English

Subject field(s)
  • Radiotelephony
CONT

When it is necessary to couple two or more signal generators to a receiver, a combining network shall be used such that each signal generator shall see a matched load when the output of the network is matched to the nominal input impedance of the receiver.

French

Domaine(s)
  • Radiotéléphonie
CONT

Lorsque il est nécessaire de coupler deux ou plusieurs générateurs de signaux à un récepteur, utiliser un réseau combinateur de sorte que soit présentée à chaque générateur de signaux une charge adaptée lorsque la sortie du réseau est adaptée à l'impédance nominale d'entrée du récepteur.

Spanish

Save record 28

Record 29 1996-04-09

English

Subject field(s)
  • Radioelectricity
DEF

constituting or relating to an arrangement of two electron tubes such that an alternating input causes them to send current through a load alternately.

CONT

push-pull circuit

CONT

push-pull amplifier

French

Domaine(s)
  • Radioélectricité
DEF

Se dit d'un montage électronique souvent utilisé dans les amplificateurs et dont les deux éléments fonctionnent constamment en opposition de phase.

OBS

L'emploi de ce terme est recommandé par le Ministère de la défense de la France.

Spanish

Save record 29

Record 30 1987-05-12

English

Subject field(s)
  • Amplifiers (Electronics)
  • Semiconductors (Electronics)
DEF

A transistor amplifier circuit in which the collector is virtually grounded, the output being taken across the emitter load, and thus the output signal voltage "follows" the input.

OBS

This is the transistorized version of the cathode follower, which uses a tube.

French

Domaine(s)
  • Amplificateurs (Électronique)
  • Semi-conducteurs (Électronique)
DEF

Amplificateur à transistor dont la tension de collecteur demeure stable contrairement à celle de l'émetteur sur lequel on prélève le signal de sortie, ce dernier est toujours en phase avec le signal d'entrée appliquée à la base.

OBS

Le gain en tension ne dépasse pas l'unité, mais celui en courant peut être important.

Spanish

Save record 30

Record 31 1986-07-04

English

Subject field(s)
  • Energy Transformation
  • Refrigeration Engineering
  • Geophysics
CONT

Geothermal air conditioning in New Zealand... The maximum heating load is 0. 5 Gcal/h(about 585 kW thermal) while the lithium bromide absorption cooling unit requires an input of 0. 575 Gcal/h(about 668 kW thermal), requiring 1. 47 heat units per single heat unit of cooling.

French

Domaine(s)
  • Transformation de l'énergie
  • Techniques du froid
  • Géophysique

Spanish

Save record 31

Record 32 1986-06-25

English

Subject field(s)
  • Air Conditioning and Heating
  • Gas and Oil Heating
  • Geophysics
CONT

Geothermal air conditioning in New Zealand... The climatic range to be contented with is from-4°C to +30°C. The maximum heating load is 0. 5 Gcal/h(about 585 kW thermal) while the lithium bromide absorption cooling unit requires an input of 0. 575 Gcal/h(about 668 kW thermal), requiring 1. 47 heat units per single heat unit of cooling.

French

Domaine(s)
  • Conditionnement de l'air et chauffage
  • Chauffage au gaz et au mazout
  • Géophysique

Spanish

Save record 32

Record 33 1980-09-17

English

Subject field(s)
  • Water Treatment (Water Supply)
  • Dust Removal
OBS

a cable slack absorber is installed on each cable near the input quadrant to maintain a minimum load on the slack cable during system operation.

French

Domaine(s)
  • Traitement des eaux
  • Dépoussiérage
OBS

chaque rattrapeur de brin mou se compose d'un corps réalisé en deux parties (...)

OBS

Le code de source complet est INCAR-SE-210, 1971, 2, 27-20-0,,, 14.

Spanish

Save record 33

Record 34 1980-03-05

English

Subject field(s)
  • Electrical Engineering
  • Electrical Systems
  • Electronics
DEF

The voltage applied between the input terminals of a network.

CONT

output voltage regulation [is the] change in output voltage, at a specified constant input voltage, resulting from a change of load current between two specified values.

French

Domaine(s)
  • Électrotechnique
  • Ensembles électrotechniques
  • Électronique
CONT

Les diodes sont bloquées l'une après l'autre, au fur et à mesure du passage par zéro de la tension entre leur bornes, de telle manière que, (...) lors de la montée de la tension d'entrée (...), la constante de multiplication de cette tension augmente graduellement.

Spanish

Save record 34

Record 35 1980-03-05

English

Subject field(s)
  • Electrical Engineering
  • Electrical Systems
  • Electronics
DEF

The change in output voltage, at a specified constant input voltage, resulting from a change of load current between two specified values.

French

Domaine(s)
  • Électrotechnique
  • Ensembles électrotechniques
  • Électronique
CONT

La stabilisation peut être encore améliorée en introduisant un amplificateur TA dans le circuit de grille du tube T. (...) On obtient ainsi une compensation des variations du circuit de charge et des variations de la tension d'entrée qui permet une régulation presque parfaite de la tension de sortie si le gain du tube amplificateur TA est suffisamment élevé.

Spanish

Save record 35

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: