TERMIUM Plus®
The Government of Canada’s terminology and linguistic data bank.
TWO GLASS TEST [5 records]
Record 1 - internal organization data 2015-10-14
Record 1, English
Record 1, Subject field(s)
- Engineering Tests and Reliability
Record 1, Main entry term, English
- four-point bending test
1, record 1, English, four%2Dpoint%20bending%20test
correct
Record 1, Abbreviations, English
Record 1, Synonyms, English
- 4-point bending test 2, record 1, English, 4%2Dpoint%20bending%20test
correct
- four-point bend test 3, record 1, English, four%2Dpoint%20bend%20test
correct
- 4-point bend test 4, record 1, English, 4%2Dpoint%20bend%20test
correct
Record 1, Textual support, English
Record number: 1, Textual support number: 1 CONT
The edge strength can be measured in a standardized four-point bending test... A piece of glass is fixed on two rollers... On the top side, two additional rollers are used to induce a defined bending force, and the force under which the glass breaks is measured. 1, record 1, English, - four%2Dpoint%20bending%20test
Record 1, French
Record 1, Domaine(s)
- Fiabilité, contrôle et essais (Ingénierie)
Record 1, Main entry term, French
- essai de flexion quatre points
1, record 1, French, essai%20de%20flexion%20quatre%20points
correct, masculine noun
Record 1, Abbreviations, French
Record 1, Synonyms, French
- essai de flexion 4 points 2, record 1, French, essai%20de%20flexion%204%20points
correct, masculine noun
Record 1, Textual support, French
Record number: 1, Textual support number: 1 CONT
Pour la flexion quatre points, la poutre repose sur deux appuis, mais deux forces G1 et G2 sont appliquées à la poutre [...] 1, record 1, French, - essai%20de%20flexion%20quatre%20points
Record 1, Spanish
Record 1, Textual support, Spanish
Record 2 - internal organization data 2010-02-10
Record 2, English
Record 2, Subject field(s)
- Engineering Tests and Reliability
- Man-Made Construction Materials
- Soil Mechanics (Engineering)
- Synthetic Fabrics
Record 2, Main entry term, English
- apparent opening size
1, record 2, English, apparent%20opening%20size
correct, see observation
Record 2, Abbreviations, English
- AOS 2, record 2, English, AOS
correct
- A.O.S. 3, record 2, English, A%2EO%2ES%2E
correct
Record 2, Synonyms, English
- equivalent opening size 4, record 2, English, equivalent%20opening%20size
see observation, obsolete
- E.O.S. 3, record 2, English, E%2EO%2ES%2E
obsolete
- E.O.S. 3, record 2, English, E%2EO%2ES%2E
Record 2, Textual support, English
Record number: 2, Textual support number: 1 DEF
For a geotextile, a property which indicates the approximate largest particle that would effectively pass through the geotextile. 5, record 2, English, - apparent%20opening%20size
Record number: 2, Textual support number: 1 CONT
The apparent opening size (AOS) or equivalent opening size (EOS) (they are equivalent terms) are defined in CW-02215 as the U.S. Standard sieve number that has openings closest in size to the openings in the fabric. The test uses known sized glass beads of designated number and determines by sieving ... that size of beads for which 5% or less pass through the fabric. 6, record 2, English, - apparent%20opening%20size
Record number: 2, Textual support number: 2 CONT
AOS(apparent opening size) is the basic indicator of the pore size of a geotextile. The AOS test involves dry sieving of glass beads and ASTM D 4751 describes the standard methodology. The AOS actually measures the near-largest pore diameter in the geotextile. Using similar terminology as soil gradation, AOS is commonly expressed as O95(based on retaining 95% of a given size glass bead). There are other indicators opening sizes that design methods have used such as O90, O98, Of or filtration opening size(FOS). When two different geotextiles(same O95 value) were compared, each geotextile might have different hydraulic behaviors. 7, record 2, English, - apparent%20opening%20size
Record number: 2, Textual support number: 1 OBS
This test was developed by the U.S. Army Corps of Engineers for evaluating woven fabrics but has been extended to cover all fabrics, including the nonwoven types. 6, record 2, English, - apparent%20opening%20size
Record number: 2, Textual support number: 2 OBS
... the "Equivalent Opening Size" (E.O.S.) ... is still occasionally used, although the internationally adopted term for the O95 value is now "Apparent Opening Size" (A.O.S.). 3, record 2, English, - apparent%20opening%20size
Record number: 2, Textual support number: 3 OBS
Compare with "filtration opening size." 8, record 2, English, - apparent%20opening%20size
Record 2, French
Record 2, Domaine(s)
- Fiabilité, contrôle et essais (Ingénierie)
- Matériaux de construction artificiels
- Mécanique des sols
- Textiles artificiels et synthétiques
Record 2, Main entry term, French
- ouverture de filtration (tamisage à sec)
1, record 2, French, ouverture%20de%20filtration%20%28tamisage%20%C3%A0%20sec%29
correct, feminine noun
Record 2, Abbreviations, French
Record 2, Synonyms, French
- ouverture de filtration (tamisage par voie sèche) 1, record 2, French, ouverture%20de%20filtration%20%28tamisage%20par%20voie%20s%C3%A8che%29
correct, feminine noun
Record 2, Textual support, French
Record number: 2, Textual support number: 1 OBS
ouverture de filtration (tamisage à sec, ou par voie sèche) : équivalents obtenus auprès d'un professeur de l'École polytechnique de Montréal, qui donne un cours intitulé «Mécanique des sols expérimentale». Selon lui, l'expression «diamètre d'ouverture de filtration» est pléonastique. 1, record 2, French, - ouverture%20de%20filtration%20%28tamisage%20%C3%A0%20sec%29
Record number: 2, Textual support number: 2 OBS
Pour les géotextiles utilisés comme filtres, on mesurera par commodité la probabilité de passage des particules de sol d'un diamètre connu. On assimile ainsi le géotextile à un tamis. On enregistre la taille maximale des particules traversant le tamis, mesure assimilée à un diamètre, d'où l'expression «diamètre de filtration». Plusieurs principes et méthodes sont actuellement utilisés pour définir cette caractéristique : tamisage à sec de billes de verre calibrées [...]; tamisage à sec de particules de sol [...]; tamisage de sol à l'humide [...]; tamisage de sol sous régime hydrodynamique. 2, record 2, French, - ouverture%20de%20filtration%20%28tamisage%20%C3%A0%20sec%29
Record number: 2, Textual support number: 3 OBS
Le critère de rétention des particules de sol est généralement exprimé par un rapport entre l'ouverture de filtration du géotextile (représentant sa porométrie) et la dimension des plus grosses particules de sol susceptible de le traverser (D). Ouverture de filtration. Diverses techniques ont été développées pour mesurer la taille des pores d'un géotextile. Elles sont divisées en trois classes : les méthodes directes (optiques ou par analyse d'images); indirectes (tamisage) ou théoriques (calcul de la porométrie). Les méthodes par tamisage sont les seules à avoir été normalisées. Le diamètre d'ouverture de filtration est défini comme la dimension d95 de la courbe cumulative des particules passant au travers le géotextile pendant le tamisage. En d'autres mots, d95 est la dimension de l'ouverture du géotextile dont 95 % de ses ouvertures sont inférieures à cette valeur. Au Canada, deux méthodes sont actuellement utilisées : le tamisage hydrodynamique qui donne le paramètre FOS (Filtration Opening Size) (CAN/CGSB 148.1-10) et le tamisage à sec qui donne le AOS (ASTM D 4751-81). Pour mesurer le FOS, on dépose sur le géotextile une quantité déterminée de billes de verre et on le soumet à une série d'immersions et d'émersions dans un bac rempli d'eau. Les particules sont alors entraînées à travers l'échantillon. Cette procédure simule des conditions que l'on retrouve dans des applications de filtration et de séparation. Selon certains, le FOS est donc le seul critère à appliquer pour la conception de filtres et de séparateurs. En effet, la procédure d'immersion et d'émersion force les particules à passer au travers du géotextile. Aussi, le fait de mouiller les particules pendant le tamisage élimine les forces d'électricité statique à la surface des particules et des fibres. Avec le tamisage à sec, les forces électrostatiques qui se développent pendant le test entraînent une agglomération des particules, même en utilisant un agent antistatiq 3, record 2, French, - ouverture%20de%20filtration%20%28tamisage%20%C3%A0%20sec%29
Record 2, Spanish
Record 2, Textual support, Spanish
Record 3 - internal organization data 2010-02-08
Record 3, English
Record 3, Subject field(s)
- Engineering Tests and Reliability
- Man-Made Construction Materials
- Soil Mechanics (Engineering)
- Synthetic Fabrics
Record 3, Main entry term, English
- filtration opening size
1, record 3, English, filtration%20opening%20size
correct, see observation
Record 3, Abbreviations, English
- FOS 1, record 3, English, FOS
correct
Record 3, Synonyms, English
Record 3, Textual support, English
Record number: 3, Textual support number: 1 CONT
AOS(apparent opening size) is the basic indicator of the pore size of a geotextile. The AOS test involves dry sieving of glass beads and ASTM D 4751 describes the standard methodology. The AOS actually measures the near-largest pore diameter in the geotextile. Using similar terminology as soil gradation, AOS is commonly expressed as O95(based on retaining 95% of a given size glass bead). There are other indicators opening sizes that design methods have used such as O90, O98, Of or filtration opening size(FOS). When two different geotextiles(same O95 value) were compared, each geotextile might have different hydraulic behaviors. 1, record 3, English, - filtration%20opening%20size
Record number: 3, Textual support number: 1 OBS
Compare with "apparent opening size." 2, record 3, English, - filtration%20opening%20size
Record 3, French
Record 3, Domaine(s)
- Fiabilité, contrôle et essais (Ingénierie)
- Matériaux de construction artificiels
- Mécanique des sols
- Textiles artificiels et synthétiques
Record 3, Main entry term, French
- ouverture de filtration (tamisage hydrodynamique)
1, record 3, French, ouverture%20de%20filtration%20%28tamisage%20hydrodynamique%29
correct, feminine noun
Record 3, Abbreviations, French
Record 3, Synonyms, French
- ouverture de filtration (tamisage par voie hydrodynamique) 1, record 3, French, ouverture%20de%20filtration%20%28tamisage%20par%20voie%20hydrodynamique%29
correct, feminine noun
Record 3, Textual support, French
Record number: 3, Textual support number: 1 OBS
ouverture de filtration (tamisage hydrodynamique, ou par voie hydrodynamique) : équivalents obtenus auprès d'un professeur de l'École polytechnique de Montréal, qui donne un cours intitulé «Mécanique des sols expérimentale». Selon lui, l'expression «diamètre d'ouverture de filtration» est pléonastique. 1, record 3, French, - ouverture%20de%20filtration%20%28tamisage%20hydrodynamique%29
Record number: 3, Textual support number: 2 OBS
Pour les géotextiles utilisés comme filtres, on mesurera par commodité la probabilité de passage des particules de sol d'un diamètre connu. On assimile ainsi le géotextile à un tamis. On enregistre la taille maximale des particules traversant le tamis, mesure assimilée à un diamètre, d'où l'expression «diamètre de filtration». Plusieurs principes et méthodes sont actuellement utilisés pour définir cette caractéristique : tamisage à sec de billes de verre calibrées [...]; tamisage à sec de particules de sol [...]; tamisage de sol à l'humide [...]; tamisage de sol sous régime hydrodynamique. 2, record 3, French, - ouverture%20de%20filtration%20%28tamisage%20hydrodynamique%29
Record number: 3, Textual support number: 3 OBS
Le critère de rétention des particules de sol est généralement exprimé par un rapport entre l'ouverture de filtration du géotextile (représentant sa porométrie) et la dimension des plus grosses particules de sol susceptible de le traverser (D). Ouverture de filtration. Diverses techniques ont été développées pour mesurer la taille des pores d'un géotextile. Elles sont divisées en trois classes : les méthodes directes (optiques ou par analyse d'images); indirectes (tamisage) ou théoriques (calcul de la porométrie). Les méthodes par tamisage sont les seules à avoir été normalisées. Le diamètre d'ouverture de filtration est défini comme la dimension d95 de la courbe cumulative des particules passant au travers le géotextile pendant le tamisage. En d'autres mots, d95 est la dimension de l'ouverture du géotextile dont 95 % de ses ouvertures sont inférieures à cette valeur. Au Canada, deux méthodes sont actuellement utilisées : le tamisage hydrodynamique qui donne le paramètre FOS (Filtration Opening Size) (CAN/CGSB 148.1-10) et le tamisage à sec qui donne le AOS (ASTM D 4751-81). Pour mesurer le FOS, on dépose sur le géotextile une quantité déterminée de billes de verre et on le soumet à une série d'immersions et d'émersions dans un bac rempli d'eau. Les particules sont alors entraînées à travers l'échantillon. Cette procédure simule des conditions que l'on retrouve dans des applications de filtration et de séparation. Selon certains, le FOS est donc le seul critère à appliquer pour la conception de filtres et de séparateurs. En effet, la procédure d'immersion et d'émersion force les particules à passer au travers du géotextile. Aussi, le fait de mouiller les particules pendant le tamisage élimine les forces d'électricité statique à la surface des particules et des fibres. Avec le tamisage à sec, les forces électrostatiques qui se développent pendant le test entraînent une agglomération des particules, même en utilisant un agent antistatiq 3, record 3, French, - ouverture%20de%20filtration%20%28tamisage%20hydrodynamique%29
Record 3, Spanish
Record 3, Textual support, Spanish
Record 4 - internal organization data 1982-08-10
Record 4, English
Record 4, Subject field(s)
- Analytical Chemistry
- Electrolysis (Electrokinetics)
- Electrochemistry
Record 4, Main entry term, English
- test solution
1, record 4, English, test%20solution
correct
Record 4, Abbreviations, English
Record 4, Synonyms, English
- unknown solution 2, record 4, English, unknown%20solution
correct
Record 4, Textual support, English
Record number: 4, Textual support number: 1 CONT
To find the pH of a test solution, the electromotive force, E, generated is measured by placing two standard electrodes(usually a glass electrode and a calomel electrode) into the test solution.... Here pH3 and E3 are values for a standard solution using the same electrodes. 1, record 4, English, - test%20solution
Record 4, French
Record 4, Domaine(s)
- Chimie analytique
- Électrolyse (Électrocinétique)
- Électrochimie
Record 4, Main entry term, French
- solution inconnue
1, record 4, French, solution%20inconnue
correct, feminine noun
Record 4, Abbreviations, French
Record 4, Synonyms, French
- solution de pH inconnu 2, record 4, French, solution%20de%20pH%20inconnu
correct, feminine noun
Record 4, Textual support, French
Record number: 4, Textual support number: 1 CONT
L'Union internationale de chimie pure et appliquée a adopté la définition suivante [de la mesure électrométrique du pH] : le pH de la solution inconnue est donné par [une équation] où pHx est le pH de la solution inconnue; pH(E) est le pH de la solution étalon (...) 1, record 4, French, - solution%20inconnue
Record 4, Spanish
Record 4, Textual support, Spanish
Record 5 - internal organization data 1976-06-19
Record 5, English
Record 5, Subject field(s)
- Chemistry
- Pharmacology
Record 5, Main entry term, English
- two glass test 1, record 5, English, two%20glass%20test
Record 5, Abbreviations, English
Record 5, Synonyms, English
Record 5, Textual support, English
Record 5, French
Record 5, Domaine(s)
- Chimie
- Pharmacologie
Record 5, Main entry term, French
- prélèvement à deux verres 1, record 5, French, pr%C3%A9l%C3%A8vement%20%C3%A0%20deux%20verres
Record 5, Abbreviations, French
Record 5, Synonyms, French
Record 5, Textual support, French
Record number: 5, Textual support number: 1 OBS
bactériologie (Manuel de Chimie clinique, Laboratoire d'hygiène, 3-gén., 1956) 1, record 5, French, - pr%C3%A9l%C3%A8vement%20%C3%A0%20deux%20verres
Record 5, Spanish
Record 5, Textual support, Spanish
Copyright notice for the TERMIUM Plus® data bank
© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau
Features
Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.
Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.
Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.
- Date Modified: