TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

WET CONNECTION [9 records]

Record 1 2016-05-04

English

Subject field(s)
  • Pipes and Fittings
  • HVAC Distribution Systems
  • Heating
CONT

The Hartford loop is a special arrangement of return piping at the boiler. Its purpose is to reduce the likelihood of an insignificant quantity of water creating a low water condition that can cause damage to a steam heating boiler. It came into general use in 1919 and was primarily designed for use with heating systems having gravity wet return. In effect, it consists of two loops of pipe forming two U-tubes. The first loop is around the boiler and the second loop is composed of the drip connection, the wet return, and a short riser called the loop riser.... The use of a Hartford loop is not recommended where the condensate is returned to the boiler by a condensate pump.

French

Domaine(s)
  • Tuyauterie et raccords
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Chauffage
CONT

La boucle de Hartford est une configuration conçue comme un des dispositifs destinés à empêcher la vidange accidentelle de la chaudière.

Spanish

Save record 1

Record 2 2016-03-07

English

Subject field(s)
  • Mineral Processing (Metallurgy)
  • Processing of Mineral Products
  • Coal Preparation
DEF

The proportion of a desired metal or mineral obtained in the treatment of an ore.

CONT

If the feed assays 10 dwt and the tailings 1 dwt, the recovery is 90%.

OBS

Recovery is better used in connection with milling operations, while extraction is especially applicable to smelting or wet chemical methods...

OBS

recovery; yield: terms standardized by ISO.

Key term(s)
  • mining recovery

French

Domaine(s)
  • Minéralurgie (Métallurgie)
  • Préparation des produits miniers
  • Préparation des charbons
DEF

Proportion de matière récupérée au cours [d'un] traitement, par rapport au matériau entrant.

OBS

Il faut préciser s'il s'agit du rendement en «poids» ou du rendement en métal.

OBS

rendement : terme normalisé par l'ISO.

Spanish

Save record 2

Record 3 2015-03-03

English

Subject field(s)
  • Plumbing Tools and Equipment
  • Equipment and Tools (Water Supply)
DEF

A machine for cutting and tapping a small hole in a pipe, such as a street main, that is either empty or carrying pressure. Two classes of tapping machines are made, designated as pressure-tapping and dry-tapping machines. They are sometimes called drilling machines.

CONT

wet connection : a connection to a water main under pressure, made by a pipe-tapping machine without interrupting service.

French

Domaine(s)
  • Appareillage et outils de plomberie
  • Équipement et outillage (Alimentation en eau)
CONT

Comme il ne peut être question d'arrêter l'eau d'un réseau ou d'une partie de réseau de ville pour créer un branchement, on fait une prise en charge à l'aide d'une machine à percer les conduites, dont le foret passe dans la lanterne du robinet de branchement (modèle à boisseau) que l'on ferme dès que la prise est faite.

Spanish

Save record 3

Record 4 2011-09-29

English

Subject field(s)
  • Pipes and Fittings
  • HVAC Distribution Systems
DEF

A vertical supply or return pipe for steam, water, or gas.

CONT

The Hartford loop is a special arrangement of return piping at the boiler.... In effect, it consists of two loops of pipe forming two U-tubes. The first loop is around the boiler and second loop is composed of the drip connection, the wet return, and a short riser called the loop riser.

OBS

riser: term officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Tuyauterie et raccords
  • Distribution et évacuation (chauffage et conditionnement d'air)
DEF

Canalisation verticale principale alimentant en eau froide et chaude, gaz, électricité, chauffage, etc., tout un groupe de logements situés à plusieurs étages autour d'une même verticale.

CONT

Système à deux tuyaux. On distingue les systèmes à distributions inférieure [...] et supérieure [...] Dans la distribution inférieure, les canalisations principales de départ et de retour sont installées au plafond du sous-sol; le départ comporte une pente ascendante depuis la chaudière jusqu'à la colonne montante la plus éloignée, et le retour une pente descendante depuis la colonne verticale la plus éloignée jusqu'à la chaudière. Les corps de chauffe sont raccordés au système de distribution par des colonnes verticales montantes et descendantes.

OBS

colonne montante : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Campo(s) temático(s)
  • Tuberías y accesorios
  • Sist. de calefacción, ventilación y acondicionamiento de aire
Save record 4

Record 5 2000-06-30

English

Subject field(s)
  • Pipes and Fittings
  • Sewers and Drainage
  • Transport of Water (Water Supply)
  • Long-Distance Pipelines
CONT

Direct tapping. Insertion of a corporation stop into a water main normally while the main is in service and under pressure. Direct tapping under pressure is commonly termed a "wet connection" or "hot tap. "Direct tapping when the water main is not in service or under pressure is commonly termed a "dry connection" or "dry tap. "

French

Domaine(s)
  • Tuyauterie et raccords
  • Égouts et drainage
  • Adduction d'eau (Alimentation en eau)
  • Canalisations à grande distance
DEF

Raccordement à une canalisation d'eau ou d'égout, effectué lorsqu'elle n'est pas utilisée ou au moment de sa construction.

Spanish

Save record 5

Record 6 2000-06-30

English

Subject field(s)
  • Plumbing
  • Water Supply
  • Transport of Water (Water Supply)
DEF

A connection to a water main under pressure, made by a pipe-tapping machine without interrupting service.

French

Domaine(s)
  • Plomberie
  • Alimentation en eau
  • Adduction d'eau (Alimentation en eau)
DEF

Raccordement d'une conduite d'eau sous pression, sans interruption de service.

CONT

Comme il ne peut être question d'arrêter l'eau d'un réseau ou d'une partie de réseau de ville pour créer un branchement, on fait une prise en charge à l'aide d'une machine à percer les conduites, dont le foret passe dans la lanterne du robinet de branchement (modèle à boisseau) que l'on ferme dès que la prise est faite.

Spanish

Save record 6

Record 7 1990-02-26

English

Subject field(s)
  • Heating
  • HVAC Distribution Systems
  • Pipes and Fittings
CONT

The return piping that carries the condensate accumulation back to the boiler and is installed below the level of the boiler water line is called a wet return. It is completely filled with water and does not carry air or steam. When the system is first filled with water or is cold, the pressure throughout the system is the same, or balances. Therefore, the water is at the same level in the boiler and drip connection as indicated by the boiler water line.

French

Domaine(s)
  • Chauffage
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Tuyauterie et raccords
CONT

Les canalisations de retour ramènent les eaux de condensation des corps de chauffe à la chaudière. La canalisation de retour horizontale, servant de collecteur aux colonnes descendantes, peut être située au-dessus du plan d'eau correspondant à la pression atmosphérique (...) : on a alors affaire à un retour sec. Cette canalisation de retour horizontale peut, au contraire, être située au-dessous de ce plan : on a alors affaire à un retour humide ou retour noyé.

Spanish

Save record 7

Record 8 1990-01-30

English

Subject field(s)
  • Heating
  • HVAC Distribution Systems
  • Pipes and Fittings
CONT

The drip connection is the vertical length of pipe connecting the remote end of the steam supply main to the wet return.

CONT

The supply main carries steam from the boiler to the radiators connected along its length. It also carries condensate accumulation from these units back to the drip connection.

French

Domaine(s)
  • Chauffage
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Tuyauterie et raccords
CONT

Les systèmes de distribution de la vapeur. Retour humide. [Système à un seul tuyau.] (...) Dans ce système le maître-tuyau distributeur se prolonge un peu plus loin que le dernier radiateur, avec pente vers son extrémité, où l'on place un robinet de dégagement permettant l'évacuation de l'air. Un tuyau d'égouttement (drip) est placé à cette extrémité et joint l'entrée de retour de la bouilloire [chaudière], pour former ce qu'on appelle le retour humide (wet return).

Spanish

Save record 8

Record 9 1975-03-11

English

Subject field(s)
  • Plumbing Tools and Equipment
  • Equipment and Tools (Water Supply)
OBS

wet connection : a connection to a water main under pressure, made by a--without interrupting service.

French

Domaine(s)
  • Appareillage et outils de plomberie
  • Équipement et outillage (Alimentation en eau)
OBS

les branchements d'abonnés sur une distribution d'eau sont généralement exécutés en charge, à l'aide d'un collier de prise en charge et d'une --. [aussi machine à percer les conduites en charge CHAPL 69 136]

Spanish

Save record 9

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: