Record 1, Main entry term, English
- contact mode atomic force microscope
1, record 1, English, contact%20mode%20atomic%20force%20microscope
correct
Record 1, Abbreviations, English
Record 1, Synonyms, English
- contact mode AFM 2, record 1, English, contact%20mode%20AFM
correct
Record 1, Textual support, English
Record number: 1, Textual support number: 1 CONT
The contact mode atomic force microscope (AFM) uses a tip that is connected to a cantilever which has a spring constant of about 0.01 - 0.3 N/m. 1, record 1, English, - contact%20mode%20atomic%20force%20microscope
Record 1, French
Record 1, Domaine(s)
- Instruments scientifiques
- Physique atomique
Record 1, Main entry term, French
- microscope à force atomique en mode contact
1, record 1, French, microscope%20%C3%A0%20force%20atomique%20en%20mode%20contact
correct, masculine noun
Record 1, Abbreviations, French
Record 1, Synonyms, French
Record 1, Textual support, French
Record number: 1, Textual support number: 1 CONT
[...] la version 3100 est composée d’un microscope à force atomique en mode contact ou en mode tapping, mode qui permet d’étudier la surface d’échantillons de toute taille. Elle est équipée de moteurs pas-à-pas qui permettent une étude exhaustive à grande échelle des échantillons. 1, record 1, French, - microscope%20%C3%A0%20force%20atomique%20en%20mode%20contact
Record 1, Spanish
Record 1, Campo(s) temático(s)
- Instrumentos científicos
- Física atómica
Record 1, Main entry term, Spanish
- microscopio de fuerza atómica en modo contacto
1, record 1, Spanish, microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20contacto
correct, masculine noun
Record 1, Abbreviations, Spanish
Record 1, Synonyms, Spanish
- AFM en modo contacto 2, record 1, Spanish, AFM%20en%20modo%20contacto
correct, masculine noun
- microscopio de fuerza atómica en modo con contacto 3, record 1, Spanish, microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20con%20contacto
correct, masculine noun
- AFM en modo con contacto 3, record 1, Spanish, AFM%20en%20modo%20con%20contacto
correct, masculine noun
Record 1, Textual support, Spanish
Record number: 1, Textual support number: 1 CONT
Microscopio de fuerza atómica [...] Tiene resolución de fracciones de angstrom. Su sonda está formada por un cantilever microscópico con una fina punta en su extremo encargada de rastrear la muestra. Puede trabajar en modo "contacto" y en modo "sin contacto". En el primer caso la punta toca la muestra y ésta ejerce una fuerza sobre la primera a medida que la sonda se desplaza sobre la muestra en el plano XY. 1, record 1, Spanish, - microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20contacto
Record number: 1, Textual support number: 2 CONT
El microscopio de fuerza atómica o AFM por sus siglas en inglés, muestrea la superficie mediante una punta muy pequeña de unos pocos micrones de largo y un diámetro más pequeño aún, de unos diez nanómetros. [...] Las fuerzas que actúan sobre el cantilever son varias. Una de ellas es la fuerza de Van der Waals que ocurre entre átomos. Esta fuerza puede ser de atracción o de repulsión, dependiendo de la distancia entre los átomos. Esto da lugar a dos modos de operación, el modo con contacto y modo sin contacto. En el modo con contacto el cantilever se sitúa a unos pocos angstroms de la superficie y la fuerza interatómica es de repulsión. En el modo sin contacto la punta se mantiene a decenas o cientos de angstroms de la superficie y las fuerzas son de atracción. 3, record 1, Spanish, - microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20contacto
Record number: 1, Textual support number: 1 OBS
AFM: por su sigla en inglés (atomic force microscope). 4, record 1, Spanish, - microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20contacto
Record 2 - internal organization data 2014-04-30
Record 2, English
Record 2, Subject field(s)
- Scientific Instruments
- Atomic Physics
Record 2, Main entry term, English
- noncontact atomic force microscope
1, record 2, English, noncontact%20atomic%20force%20microscope
correct
Record 2, Abbreviations, English
- NC-AFM 1, record 2, English, NC%2DAFM
correct
Record 2, Synonyms, English
- AFM in the non-contact mode 2, record 2, English, AFM%20in%20the%20non%2Dcontact%20mode
correct
Record 2, Textual support, English
Record number: 2, Textual support number: 1 CONT
Since 1995, the noncontact atomic force microscope (NC-AFM) has achieved remarkable progress. Based on nanomechanical methods, the NC-AFM detects the weak attractive force between the tip of a cantilever and a sample surface. This method has the following characteristics: it has true atomic resolution; it can measure atomic force interactions ... 1, record 2, English, - noncontact%20atomic%20force%20microscope
Record 2, Key term(s)
- non-contact atomic force microscope
- AFM in the noncontact mode
Record 2, French
Record 2, Domaine(s)
- Instruments scientifiques
- Physique atomique
Record 2, Main entry term, French
- microscope à force atomique en mode non-contact
1, record 2, French, microscope%20%C3%A0%20force%20atomique%20en%20mode%20non%2Dcontact
correct, masculine noun
Record 2, Abbreviations, French
Record 2, Synonyms, French
- microscope AFM en régime de non-contact 2, record 2, French, microscope%20AFM%20en%20r%C3%A9gime%20de%20non%2Dcontact
masculine noun
- NC-AFM 2, record 2, French, NC%2DAFM
masculine noun
- NC-AFM 2, record 2, French, NC%2DAFM
Record 2, Textual support, French
Record number: 2, Textual support number: 1 CONT
Microscope AFM en régime de non-contact (NC) avec détection par modulation de fréquence. Dans ce type d'instrument, la sonde oscille à sa fréquence propre de l'ordre de 40 kHz. Lorsque la sonde se trouve à proximité immédiate d'une surface de référence, les effets des forces de Van der Waals modifient légèrement cette oscillation. La détection de ces modulations permet de desceller la structure subnanométrique de la surface de référence (l'échantillon). Sont inclus des scanners à tube piezo pour le NC-AFM avec amplificateurs haute tension. 2, record 2, French, - microscope%20%C3%A0%20force%20atomique%20en%20mode%20non%2Dcontact
Record number: 2, Textual support number: 1 OBS
Dans le mode non-contact, la pointe [du microscope] est attirée. Les forces attractives étant très faibles, il faut travailler au froid et sous vide pour éviter l’humidité et l’agitation thermique. 1, record 2, French, - microscope%20%C3%A0%20force%20atomique%20en%20mode%20non%2Dcontact
Record 2, Spanish
Record 2, Campo(s) temático(s)
- Instrumentos científicos
- Física atómica
Record 2, Main entry term, Spanish
- microscopio de fuerza atómica en modo sin contacto
1, record 2, Spanish, microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20sin%20contacto
correct, masculine noun
Record 2, Abbreviations, Spanish
Record 2, Synonyms, Spanish
- AFM en modo sin contacto 2, record 2, Spanish, AFM%20en%20modo%20sin%20contacto
correct, masculine noun
- microscopio de fuerza atómica en modo de no-contacto 3, record 2, Spanish, microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20de%20no%2Dcontacto
correct, masculine noun
- AFM en modo de no-contacto 3, record 2, Spanish, AFM%20en%20modo%20de%20no%2Dcontacto
correct, masculine noun
- AFM en régimen de no contacto 4, record 2, Spanish, AFM%20en%20r%C3%A9gimen%20de%20no%20contacto
correct, masculine noun
Record 2, Textual support, Spanish
Record number: 2, Textual support number: 1 CONT
El microscopio de fuerza atómica o AFM por sus siglas en inglés, muestrea la superficie mediante una punta muy pequeña de unos pocos micrones de largo y un diámetro más pequeño aún, de unos diez nanómetros. [...] Las fuerzas que actúan sobre el cantilever son varias. Una de ellas es la fuerza de Van der Waals que ocurre entre átomos. Esta fuerza puede ser de atracción o de repulsión, dependiendo de la distancia entre los átomos. Esto da lugar a dos modos de operación, el modo con contacto y modo sin contacto. En el modo con contacto el cantilever se sitúa a unos pocos angstroms de la superficie y la fuerza interatómica es de repulsión. En el modo sin contacto la punta se mantiene a decenas o cientos de angstroms de la superficie y las fuerzas son de atracción. 2, record 2, Spanish, - microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20sin%20contacto
Record number: 2, Textual support number: 2 CONT
El principio de funcionamiento del microscopio de fuerza magnética es, en principio, el de un AFM en régimen de no contacto: un soporte flexible fijado a un extremo y una punta montada en el otro extremo. 4, record 2, Spanish, - microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20sin%20contacto
Record number: 2, Textual support number: 1 OBS
En el modo “sin contacto” el cantilever oscila a una frecuencia próxima a la resonancia y son las interacciones electrostáticas entre punta y muestra las que modifican la oscilación del cantilever (en frecuencia, amplitud o fase). 5, record 2, Spanish, - microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20sin%20contacto
Record number: 2, Textual support number: 2 OBS
AFM: por su sigla en inglés (atomic force microscope). 6, record 2, Spanish, - microscopio%20de%20fuerza%20at%C3%B3mica%20en%20modo%20sin%20contacto
Copyright notice for the TERMIUM Plus® data bank
© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau
Features
Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.
Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.
Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.
- Date Modified: