Record 1 2011-08-30

English

Subject field(s)
  • Chemistry
  • Fires and Explosions
  • Combustion and Fuels (Fireplaces)
DEF

... any liquid having a flash point at or above 37.8 ° C and below 93.3 ° C.

CONT

Strictly speaking, flammable and combustible liquids are not a fire cause ... . More correctly, they are contributing factors because a spark or other minor source of ignition which might otherwise be harmless may cause fire or explosion in the presence of flammable vapors.

French

Domaine(s)
  • Chimie
  • Feux et explosions
  • Combustion et combustibles (Foyers)
DEF

Liquide dont le point d’éclair est égal ou supérieur à 37.8 ° C mais inférieur à 93.3 ° C.

DEF

Tout liquide qui ne présente pas les caractéristiques d’une autre classe de risque telles qu'elles sont précisées dans cette Réglementation [sur le transport des march. dangereuses] et dont le point d’éclair en creuset fermé est égal ou supérieur à 37, 8 C(100 F.), mais inférieur à 93, 3 C(200 F.) et contenu dans un emballage d’une capacité supérieure à 420 litres.

OBS

Tout mélange, dont un ou plusieurs composants ayant un point d’éclair égal ou supérieur à 93,3 C (200 F.) représentent au moins 99% du volume total du mélange, n’est pas considéré comme un liquide combustible.

Spanish

Campo(s) temático(s)
  • Química
  • Fuegos y explosiones
  • Combustión y combustibles (Hogares o chimeneas)
DEF

Aquel cuyo punto de inflamación es superior a 38°C.

Save record 1

Record 2 2009-04-15

English

Subject field(s)
  • Equipment (Chemistry)
  • Petrochemistry
CONT

Flash point. The lowest temperature at which vapors from a volatile liquid will ignite momentarily upon the application of a small flame under specified conditions; test conditions can be either open- or closed-cup.

French

Domaine(s)
  • Équipement (Chimie)
  • Chimie du pétrole
CONT

Point d’éclair. L'essai consiste à chauffer dans un creuset ouvert ou fermé à vitesse déterminée un échantillon du produit jusqu'à ce qu'une quantité suffisante d’éléments volatils soit vaporisée et puisse être enflammée par une petite flamme que l'on déplace au-dessus du creuset. Dès qu'une légère explosion se produit, on note la température du produit, qui correspond au point d’éclair ou flash point.

OBS

«Vase clos» semble être le terme le plus fréquemment utilisé. C’est celui que l’on retrouve le plus souvent dans les normes portant sur les produits pétroliers.

Key term(s)
  • coupelle fermée

Spanish

Campo(s) temático(s)
  • Equipo (Química)
  • Petroquímica
CONT

Por líquidos inflamables se entienden aquellos líquidos o mezcla de líquidos, o líquidos con sólidos en solución o suspensión (por ejemplo pinturas, barnices, lacas, etcétera, pero sin incluir sustancias o desechos clasificados de otra manera debido a sus características peligrosas) que emiten vapores inflamables a temperaturas no mayores de 60,5°C, en ensayos con cubeta cerrada, o no más de 65,6°C, [en] ensayos con cubeta abierta [...]

Save record 2

Record 3 2009-04-15

English

Subject field(s)
  • Equipment (Chemistry)
  • Petrochemistry
CONT

Flash point. The lowest temperature at which vapors from a volatile liquid will ignite momentarily upon the application of a small flame under specified conditions; test conditions can be either open- or closed-cup.

French

Domaine(s)
  • Équipement (Chimie)
  • Chimie du pétrole
CONT

Point d’éclair. L'essai consiste à chauffer dans un creuset ouvert ou fermé à vitesse déterminée un échantillon du produit jusqu'à ce qu'une quantité suffisante d’éléments volatils soit vaporisée et puisse être enflammée par une petite flamme que l'on déplace au-dessus du creuset. Dès qu'une légère explosion se produit, on note la température du produit, qui correspond au point d’éclair ou flash point.

OBS

«Vase ouvert» semble être le terme le plus fréquemment utilisé. C’est celui que l’on retrouve le plus dans les normes portant sur les produits pétroliers.

Spanish

Campo(s) temático(s)
  • Equipo (Química)
  • Petroquímica
CONT

Punto de incendio: Es la temperatura más baja a la que un líquido contenido en un recipiente abierto, comienza a emitir vapores con suficiente velocidad para propiciar la combustión continuada.

CONT

En la tabla adjunta se incluyen los puntos de explosión de diversos aceites y compuestos orgánicos industriales, obtenidos por el método del recipiente abierto.

Save record 3

Record 4 2000-02-09

English

Subject field(s)
  • Equipment (Chemistry)
  • Petrochemistry
DEF

[A] device to determine the ASTM flash point of fuel oils and cut back asphalts and other viscous materials and suspensions of solids.

OBS

ASTM D93-80, dated August 29, 1980: Standard Test Methods for Flash Point by Pensky-Martens Closed Tester. [Source: SOR/88-64, Hazardous Products Act, Schedule IV.].

OBS

Strictly speaking, the closed cup is a component of the apparatus but it is often used to designate the whole device.

French

Domaine(s)
  • Équipement (Chimie)
  • Chimie du pétrole
DEF

Appareil à creuset fermé pour essais d’inflammabilité des pétroles et des huiles.

CONT

Définition du point d’éclair :[...] le creuset fermé Pensky-Martens(ASTM D-93 ou IP-34) ou le creuset fermé Setaflash(ASTM D-3243 ou 3278) sera utilisé.

OBS

Le creuset fermé(ou vase clos) ne constitue en réalité qu'une partie de l'appareil. Cependant, par extension, ces expressions désignent aussi l'appareil dans son entier.

OBS

Nous n’avons pas trouvé d’abréviation française correspondante.

Key term(s)
  • vase clos Pensky-Martens

Spanish

Save record 4

Record 5 1998-08-21

English

Subject field(s)
  • Medical Instruments and Devices
  • Dentistry
Key term(s)
  • crucible tong

French

Domaine(s)
  • Instruments et appareillages médicaux
  • Dentisterie
CONT

Pince à creuset, acier inox. Pour manipuler les creusets avec une prise ferme(...)

Spanish

Save record 5

Record 6 1998-07-10

English

Subject field(s)
  • Equipment (Chemistry)
  • Analytical Chemistry
  • Petrochemistry
CONT

[20/1/88. Canada Gazette Part II, vol. 122, no. 2. SOR/88-64. Hazardous Products Act.] Schedule IV. Methods of testing for flash point of a liquid ... is ... the appropriate test in the "Standard Test Methods for Flash Point by Setaflash Closed Tester", ASTM D3828-81, dated August 28, 1981 ... [or] the appropriate test in the "Standard Test Methods for Flash Point of Liquids by Setaflash Closed-Cup Apparatus", ASTM D3278-82, dated August 28, 1981.

Key term(s)
  • Setaflash closed-cup tester
  • Seta closed-cup tester
  • Seta closed tester
  • SCC

French

Domaine(s)
  • Équipement (Chimie)
  • Chimie analytique
  • Chimie du pétrole
OBS

(en vase clos). Appareil à creuset fermé(ou vase clos) pour la détermination du point d’éclair.

OBS

D’autres appareils de même nature sont décrits plus abondamment en banque. Voir «Tag closed tester», «Pensky-Martens closed tester», «Abel closed tester» et «Cleveland open-cup tester».

OBS

Les termes «vase» et «creuset», qui désignent en réalité une partie de l’appareil, sont souvent utilisés pour désigner l’appareil lui-même.

Spanish

Save record 6

Record 7 1990-02-01

English

Subject field(s)
  • Equipment (Chemistry)
  • Petrochemistry
DEF

A laboratory instrument used in testing the flash point of kerosine and other volatile oils having flash points below 120°F (49°C); the oil is contained in a closed cup which is heated by a fixed flame below and a movable flame above.

OBS

The terms proposed are modelled on "Abel flash point test", "Pensky-Martens closed cup apparatus" and "Tag closed tester" (see those records).

OBS

According to source ERENGA, the terms "Abel apparatus" and "Abel-Pensky apparatus" designate the same tester, but we have been unable to confirm this in other sources. See also "Abel-Pensky tester."

French

Domaine(s)
  • Équipement (Chimie)
  • Chimie du pétrole
CONT

La présente norme [AFNOR no M07-011] a pour objet de décrire une méthode de détermination du point d’éclair, en vase clos, des produits et mélanges pétroliers liquides [...] La prise d’essai contenue dans le vase d’un appareil Abel est chauffée, à l’abri des courants d’air, lentement à une vitesse uniforme. On dirige la flamme d’une veilleuse sur les vapeurs à des intervalles réguliers et on prend comme point d’éclair la plus faible température pour laquelle l’application de cette flamme provoque l’inflammation de la vapeur au-dessus de la prise d’essai. [...] L’appareil [...] comprend essentiellement : - un vase, - un couvercle, - un bain de chauffage, - les thermomètres du vase et du bain d’eau - un métronome.

OBS

Propositions : à partir des expressions «appareils à vase clos»(norme AFNOR T30-051) et «appareils à creuset fermé»(norme ISO 1523).

OBS

creuset fermé : Au sens strict, «creuset fermé» désigne une partie seulement de l'appareil. Cependant, comme en témoigne le contexte qui suit, cette expression sert aussi à désigner tout l'appareil lui-même.

CONT

Définition du point d’éclair :[...] Pour un liquide homogène à phase simple dont la viscosité cinématique est inférieure à 5, 82 centistokes [...], le creuset fermé Tag(ASTM D-56), le creuset fermé Abel(IP-33) ou le creuset fermé Setaflash(ASTM D-3243 ou 3278), sera utilisé.

Spanish

Save record 7

Record 8 1989-11-06

English

Subject field(s)
  • Analytical Chemistry
  • Thermodynamics

French

Domaine(s)
  • Chimie analytique
  • Thermodynamique
DEF

Liquides dont le point d’éclair est inférieur à-18°C en creuset fermé.

Spanish

Save record 8

Record 9 1989-10-31

English

Subject field(s)
  • Analytical Chemistry

French

Domaine(s)
  • Chimie analytique
CONT

Classe 3 [des marchandises dangereuses] : Matières liquides inflammables.(...) D'après le point d’éclair de la marchandise il y a lieu de distinguer :(...) Classe 3. 3 : Groupe à point d’éclair élevé : Liquides dont le point d’éclair est égal ou supérieur à 23 degrés C en creuset fermé et inférieur ou égal à 61 degrés C en creuset fermé.

Spanish

Save record 9

Record 10 1989-10-30

English

Subject field(s)
  • Chemistry
  • Fires and Explosions

French

Domaine(s)
  • Chimie
  • Feux et explosions
CONT

Classe 3 : Matières liquides inflammables. [...] D'après le point d’éclair de la marchandise il y a lieu de distinguer :[...] Classe 3. 2 : Groupe à point d’éclair moyen : Liquides dont le point d’éclair est égal ou supérieur à-18°C en creuset fermé et inférieur à 23°C en creuset fermé.

Spanish

Save record 10

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: