TERMIUM Plus®
The Government of Canada’s terminology and linguistic data bank.
SPECTROMETRE MASSE PLASMA INDUCTIF MULTICOLLECTION [3 records]
Record 1 - internal organization data 2010-03-01
Record 1, English
Record 1, Subject field(s)
- Scientific Instruments
- Analytical Chemistry
- Environmental Studies and Analyses
- Geophysics
Record 1, Main entry term, English
- multiple collector inductively coupled plasma mass spectrometer
1, record 1, English, multiple%20collector%20inductively%20coupled%20plasma%20mass%20spectrometer
correct
Record 1, Abbreviations, English
- MC-ICP-MS 1, record 1, English, MC%2DICP%2DMS
correct
Record 1, Synonyms, English
- multiple collector ICP-MS 1, record 1, English, multiple%20collector%20ICP%2DMS
correct
- MC-ICP-MS 1, record 1, English, MC%2DICP%2DMS
correct
- MC-ICP-MS 1, record 1, English, MC%2DICP%2DMS
- multicollector inductively coupled plasma mass spectrometer 2, record 1, English, multicollector%20inductively%20coupled%20plasma%20mass%20spectrometer
correct
- MC-IC-MS 3, record 1, English, MC%2DIC%2DMS
correct
- MC-IC-MS 3, record 1, English, MC%2DIC%2DMS
- multi-collector sector ICP-MS 4, record 1, English, multi%2Dcollector%20sector%20ICP%2DMS
correct
- MC-ICP-MS 4, record 1, English, MC%2DICP%2DMS
correct
- MC-ICP-MS 4, record 1, English, MC%2DICP%2DMS
- multi-collector ICP-MS 5, record 1, English, multi%2Dcollector%20ICP%2DMS
correct
- MC-ICP-MS 5, record 1, English, MC%2DICP%2DMS
correct
- MC-ICP-MS 5, record 1, English, MC%2DICP%2DMS
Record 1, Textual support, English
Record number: 1, Textual support number: 1 CONT
The combination of metrological weighing, the measurement of isotope amount ratios by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) and the use of high-purity reference materials are the cornerstones to achieve improved results for the amount content of lead in wine by the reversed isotope dilution technique. 3, record 1, English, - multiple%20collector%20inductively%20coupled%20plasma%20mass%20spectrometer
Record number: 1, Textual support number: 2 CONT
Multi-Collector ICP-MS. The Neptune Multicollector Inductively Coupled Plasma Mass Spectrometer (MC-ICP-MS) combines the ability of the Inductively-Coupled Plasma to efficiently ionise most elements, with the precision isotope ratio measurement of a multicollector mass spectrometer. 5, record 1, English, - multiple%20collector%20inductively%20coupled%20plasma%20mass%20spectrometer
Record 1, French
Record 1, Domaine(s)
- Instruments scientifiques
- Chimie analytique
- Études et analyses environnementales
- Géophysique
Record 1, Main entry term, French
- spectromètre de masse à source à plasma inductif et collection d'ions multiple
1, record 1, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif%20et%20collection%20d%27ions%20multiple
correct, masculine noun
Record 1, Abbreviations, French
- MC-ICP-MS 1, record 1, French, MC%2DICP%2DMS
correct, masculine noun
Record 1, Synonyms, French
- spectromètre de masse à source plasmique et collecteurs multiples 2, record 1, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20plasmique%20et%20collecteurs%20multiples
correct, masculine noun
- MC-ICP-MS 3, record 1, French, MC%2DICP%2DMS
correct, masculine noun
- MC-ICP-MS 3, record 1, French, MC%2DICP%2DMS
- spectromètre de masse à plasma inductif et multicollection 3, record 1, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20plasma%20inductif%20et%20multicollection
correct, masculine noun
- MC-ICP-MS 4, record 1, French, MC%2DICP%2DMS
correct, masculine noun
- MC-ICP-MS 4, record 1, French, MC%2DICP%2DMS
- spectromètre de masse à source plasma et multicollecteur 4, record 1, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20plasma%20et%20multicollecteur
correct, masculine noun
- ICP/MS à multicollection 5, record 1, French, ICP%2FMS%20%C3%A0%20multicollection
correct, masculine noun
Record 1, Textual support, French
Record number: 1, Textual support number: 1 CONT
Le spectromètre de masse à source plasma et multicollecteur (MC-ICP-MS) est un appareil de choix pour les analyses isotopiques de haute résolution sur roches et sédiments meubles. 4, record 1, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif%20et%20collection%20d%27ions%20multiple
Record number: 1, Textual support number: 2 CONT
ICP/MS à secteur magnétique et multicollection «Neptune». 5, record 1, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif%20et%20collection%20d%27ions%20multiple
Record number: 1, Textual support number: 1 OBS
Il existe plusieurs types de spectromètres de masse à plasma inductif, selon les analyseurs(secteur magnétique ou quadripole). En bref, un spectromètre se compose de trois parties : une source(torche à plasma, ICP) ;un analyseur(séparateur magnétique, quadripole ou hexapole) ;un détecteur(collecteurs simples ou multiples). Les expressions qui suivent servent à désigner deux nouvelles générations d’ICP-MS : le MC-ICP-MS(spectromètre de masse à plasma inductif et multicollection, où de multiples détecteurs sont utilisés dans différentes combinaisons, et le HR-ICP-SM(spectromètre de masse à plasma inductif à haute résolution, qui présente une amélioration au niveau de la source). [Renseignements obtenus de l'Université de Liège, Département de géologie, janvier 2005] 3, record 1, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif%20et%20collection%20d%27ions%20multiple
Record number: 1, Textual support number: 1 PHR
MC-ICP-MS à haute résolution, MC-ICP-MS à secteur magnétique, MC-ICP-MS haute résolution, MC-ICP-MS Neptune. 3, record 1, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif%20et%20collection%20d%27ions%20multiple
Record 1, Spanish
Record 1, Textual support, Spanish
Record 2 - internal organization data 2010-03-01
Record 2, English
Record 2, Subject field(s)
- Scientific Instruments
- Analytical Chemistry
- Environmental Studies and Analyses
- Geophysics
Record 2, Main entry term, English
- inductively-coupled plasma mass spectrometer
1, record 2, English, inductively%2Dcoupled%20plasma%20mass%20spectrometer
correct
Record 2, Abbreviations, English
- ICP-MS 1, record 2, English, ICP%2DMS
correct
Record 2, Synonyms, English
- inductively coupled plasma mass spectrometer 2, record 2, English, inductively%20coupled%20plasma%20mass%20spectrometer
correct
- ICP-MS 3, record 2, English, ICP%2DMS
correct
- ICP-MS 3, record 2, English, ICP%2DMS
Record 2, Textual support, English
Record number: 2, Textual support number: 1 CONT
A VG PlasmaQuad Turbo 2+ Inductively Coupled Plasma Mass Spectrometer ... achieves sub-ppb detection limits on solutions for up to 2/3rd of the elements on the periodic table with sub-ppt detection limits for up to 1/3rd of the elements. 4, record 2, English, - inductively%2Dcoupled%20plasma%20mass%20spectrometer
Record 2, French
Record 2, Domaine(s)
- Instruments scientifiques
- Chimie analytique
- Études et analyses environnementales
- Géophysique
Record 2, Main entry term, French
- spectromètre de masse à source à plasma inductif
1, record 2, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif
correct, masculine noun
Record 2, Abbreviations, French
- ICP-MS 1, record 2, French, ICP%2DMS
correct, masculine noun
Record 2, Synonyms, French
- spectromètre de masse à plasma inductif 2, record 2, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20plasma%20inductif
correct, masculine noun
- ICP-MS 3, record 2, French, ICP%2DMS
correct, masculine noun
- ICP-MS 3, record 2, French, ICP%2DMS
- spectromètre de masse à source plasma 3, record 2, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20plasma
correct, masculine noun
Record 2, Textual support, French
Record number: 2, Textual support number: 1 CONT
[Le] spectromètre de masse à source plasma (ICP-MS) [est un instrument réalisé grâce à une] technique de couplage entre une torche à plasma et un spectromètre de masse [qui] permet de réaliser des dosages quantitatifs de la majorité des éléments de la classification périodique. Les limites de détection sont de l’ordre du ng/l (10-9 grammes par litre) pour les solutions. 4, record 2, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif
Record number: 2, Textual support number: 1 OBS
Il existe plusieurs types de spectromètres de masse à plasma inductif, selon les analyseurs(secteur magnétique ou quadripole). En bref, un spectromètre se compose de trois parties : une source(torche à plasma, ICP) ;un analyseur(séparateur magnétique, quadripole ou hexapole) ;un détecteur(collecteurs simples ou multiples). Les expressions qui suivent servent à désigner deux nouvelles générations d’ICP-MS : le MC-ICP-MS(spectromètre de masse à plasma inductif et multicollection, où de multiples détecteurs sont utilisés dans différentes combinaisons, et le HR-ICP-MS(spectromètre de masse à plasma inductif à haute résolution, qui présente une amélioration au niveau de la source). [Renseignements obtenus de l'Université de Liège, Département de géologie, janvier 2005] 5, record 2, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20%C3%A0%20plasma%20inductif
Record 2, Spanish
Record 2, Textual support, Spanish
Record 3 - internal organization data 2010-02-17
Record 3, English
Record 3, Subject field(s)
- Scientific Instruments
- Analytical Chemistry
- Environmental Studies and Analyses
- Geophysics
Record 3, Main entry term, English
- high resolution inductively coupled plasma mass spectrometer
1, record 3, English, high%20resolution%20inductively%20coupled%20plasma%20mass%20spectrometer
correct
Record 3, Abbreviations, English
- HR-ICP-MS 1, record 3, English, HR%2DICP%2DMS
correct
Record 3, Synonyms, English
Record 3, Textual support, English
Record number: 3, Textual support number: 1 CONT
Preliminary investigation into the use of a high resolution inductively coupled plasma-mass spectrometer with laser ablation for bulk analysis of geological materials fused with Li2B4O7. 1, record 3, English, - high%20resolution%20inductively%20coupled%20plasma%20mass%20spectrometer
Record number: 3, Textual support number: 1 PHR
High resolution double-focussing, magnetic sector inductively coupled plasma-mass spectrometer. 2, record 3, English, - high%20resolution%20inductively%20coupled%20plasma%20mass%20spectrometer
Record 3, French
Record 3, Domaine(s)
- Instruments scientifiques
- Chimie analytique
- Études et analyses environnementales
- Géophysique
Record 3, Main entry term, French
- spectromètre de masse à plasma inductif à haute résolution
1, record 3, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20plasma%20inductif%20%C3%A0%20haute%20r%C3%A9solution
correct, masculine noun
Record 3, Abbreviations, French
- HR ICP-MS 1, record 3, French, HR%20ICP%2DMS
correct, masculine noun
- HR-ICP-MS 2, record 3, French, HR%2DICP%2DMS
correct, masculine noun
Record 3, Synonyms, French
- spectromètre de masse à plasma couplé inductivement haute résolution 3, record 3, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20plasma%20coupl%C3%A9%20inductivement%20haute%20r%C3%A9solution
correct, masculine noun
- ICP-MS HR 3, record 3, French, ICP%2DMS%20HR
correct, masculine noun, less frequent
- ICP-MS HR 3, record 3, French, ICP%2DMS%20HR
- spectromètre de masse à source plasma haute résolution 4, record 3, French, spectrom%C3%A8tre%20de%20masse%20%C3%A0%20source%20plasma%20haute%20r%C3%A9solution
correct, masculine noun
- ICP-MS de haute résolution 5, record 3, French, ICP%2DMS%20de%20haute%20r%C3%A9solution
correct, masculine noun
Record 3, Textual support, French
Record number: 3, Textual support number: 1 CONT
Cet article présente les résultats préliminaires obtenus avec un ICP-MS de haute résolution, à double système de focalisation et secteur magnétique (HR-ICP-MS) couplé à un laser ultra-violet (LA) dans le cadre d’analyses totales de matériaux géologiques fondus avec Li2B4O7. 5, record 3, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20plasma%20inductif%20%C3%A0%20haute%20r%C3%A9solution
Record number: 3, Textual support number: 1 OBS
Il existe plusieurs types de spectromètres de masse à plasma inductif, selon les analyseurs(secteur magnétique ou quadripole). En bref, un spectromètre se compose de trois parties : une source(torche à plasma, ICP) ;un analyseur(séparateur magnétique, quadripole ou hexapole) ;un détecteur(collecteurs simples ou multiples). Les expressions qui suivent servent à désigner deux nouvelles générations d’ICP-MS : le MC-ICP-MS(spectromètre de masse à plasma inductif et multicollection, où de multiples détecteurs sont utilisés dans différentes combinaisons, et le HR-ICP-SM(spectromètre de masse à plasma inductif à haute résolution, qui présente une amélioration au niveau de la source). [Renseignements obtenus de l'Université de Liège, Département de géologie, janvier 2005] 6, record 3, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20plasma%20inductif%20%C3%A0%20haute%20r%C3%A9solution
Record number: 3, Textual support number: 1 PHR
ICP-MS de haute résolution, à double système de focalisation et secteur magnétique. 6, record 3, French, - spectrom%C3%A8tre%20de%20masse%20%C3%A0%20plasma%20inductif%20%C3%A0%20haute%20r%C3%A9solution
Record 3, Spanish
Record 3, Textual support, Spanish
Copyright notice for the TERMIUM Plus® data bank
© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau
Features
Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.
Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.
Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.
- Date Modified: