TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

CALCUL DEBIT [22 records]

Record 1 2024-02-15

English

Subject field(s)
  • Scientific Research
  • Informatics
CONT

"Digital research infrastructure" refers to the elements required to perform data- and computationally intensive research and data management. It includes high-performance computing, storage, high-speed networks and other resources.

French

Domaine(s)
  • Recherche scientifique
  • Informatique
CONT

L'«infrastructure de recherche numérique» désigne les éléments requis pour effectuer des recherches et de la gestion de données nécessitant de grandes quantités de données et de calculs. Elle comprend le calcul de haute performance, le stockage, les réseaux à haut débit et d’autres ressources.

Spanish

Save record 1

Record 2 2023-04-20

English

Subject field(s)
  • Oil Production
DEF

The procedure to be used to convert raw meter output to a measured quantity of petroleum or water.

French

Domaine(s)
  • Production pétrolière
DEF

Méthode utilisée pour convertir le débit brut d’un compteur en une quantité mesurée d’hydrocarbures ou d’eau.

Spanish

Save record 2

Record 3 2022-11-29

English

Subject field(s)
  • Mathematics
  • Oil and Natural Gas Extraction
CONT

... the permeabilities of the fracture network have to be determined. This can be reliably achieved from a flow calculation carried out on a geometrical model representative of the fracture network.

French

Domaine(s)
  • Mathématiques
  • Extraction du pétrole et du gaz naturel

Spanish

Save record 3

Record 4 2016-11-23

English

Subject field(s)
  • Radiation Protection
DEF

For irradiations that deliver the same accumulated dose, the factor used in computing dose equivalent to allow for differences in absorbed dose rate and irradiation time.

OBS

time factor: term standardized by ISO.

OBS

time factor: term extracted from the “Glossaire de l’énergie nucléaire” and reproduced with permission of the Organisation for Economic Co-operation and Development.

French

Domaine(s)
  • Radioprotection
DEF

Pour des radioexpositions provoquant la même dose cumulée, facteur employé dans le calcul de l'équivalent de dose pour tenir compte des différences dans le débit de dose absorbée et le temps de radioexposition.

OBS

facteur de temps : terme normalisé par l’ISO.

OBS

facteur de temps : terme extrait du «Glossaire de l’énergie nucléaire» et reproduit avec l’autorisation de l’Organisation de coopération et de développement économiques.

Spanish

Save record 4

Record 5 2015-07-07

English

Subject field(s)
  • Real Estate
DEF

The adjustment of accounts between the vendor and the purchaser of real property relating to the sale price, taxes, public utilities, mortgage, fuel, etc.

OBS

The vendor pays all his expenses to that date (such as his proportional share of fuel, real estate taxes etc.). He credits money prepaid and debits bills not paid; the end calculation will show either a credit or a debit. The closing statement is normally prepared by the lawyer, or notary in Quebec.

French

Domaine(s)
  • Immobilier
DEF

Rajustement des comptes entre le vendeur et l’acheteur du bien réel, relativement au prix de vente, à l’impôt foncier, aux frais hypothécaires, de services publics et de combustible, etc.

OBS

Le vendeur règle tous ses frais à ce jour, soit sa part de frais de combustible, d’impôt foncier, etc. Il crédite les sommes payées d’avance et débite les factures impayées; le calcul final indiquera un crédit ou un débit. En règle générale, le relevé de clôture est préparé par l'avocat ou le notaire(au Québec).

Spanish

Save record 5

Record 6 2015-05-08

English

Subject field(s)
  • Nuclear Physics
DEF

A model for the calculation of effective thermal cross-sections based on the assumption of a neutron flux density per unit energy interval that is Maxwellian for thermal neutrons and varies inversely with energy for epithermal neutrons.

OBS

Westcott model: term and definition standardized by ISO.

French

Domaine(s)
  • Physique nucléaire
DEF

Modèle utilisé pour le calcul de la section efficace thermique effective, dans lequel le débit de fluence de neutrons par intervalle unitaire d’énergie est maxwellien pour les neutrons thermiques et inversement proportionnel à l'énergie pour les neutrons épithermiques.

OBS

modèle de Westcott : terme et définition normalisés par l’ISO.

Spanish

Save record 6

Record 7 2015-04-29

English

Subject field(s)
  • Nuclear Physics
DEF

A theory for the calculation of neutron attenuation in certain radiation shield materials treating the attenuation process in two steps: initially, a source of first-collision neutrons is determined by means of removal cross-sections; then, the resulting neutron flux density is calculated by diffusion theory.

OBS

removal-diffusion theory: term and definition standardized by ISO.

French

Domaine(s)
  • Physique nucléaire
DEF

Théorie pour le calcul de l'atténuation neutronique dans certains matériaux écrans traitant le processus d’atténuation en deux étapes : d’abord une source de neutrons de première collision est déterminée au moyen des sections efficaces de déplacement, ensuite le débit de fluence neutronique résultant est calculé par la théorie de la diffusion.

OBS

théorie de déplacement-diffusion : terme et définition normalisés par l’ISO.

Spanish

Save record 7

Record 8 2013-10-02

English

Subject field(s)
  • Nuclear Physics
DEF

A method for calculating the attenuation of neutron and gamma-radiation by using the transport equation to determine spatial moments of particle flux density.

OBS

mean range: term and definition standardized by ISO in 1997.

French

Domaine(s)
  • Physique nucléaire
DEF

Méthode de calcul de l'atténuation de rayonnements neutroniques et gamma utilisant l'équation du transport pour déterminer les moments spatiaux du débit de fluence de particules.

OBS

méthode des moments : terme et définition normalisés par l’ISO en 1997.

Spanish

Save record 8

Record 9 - external organization data 2011-04-27

English

Subject field(s)
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
DEF

... the corresponding radiation dose equivalent rate determined by an appropriate instrument, by calculation, or, for neutron flux densities, through conversion ...

CONT

Every person who removes any prescribed substance from or inserts any prescribed substance into an exposure device shall measure the radiation levels and radiation exposure dosages during the course of and forthwith after the completion of the removal or insertion and submit the measurements to the licensee.

CONT

Both radiographic sources were now projected out, and the qualified operator attempts to reduce the persistent radiation levels by repeatedly projecting and retracting the cobalt 60 radiographic source ...

French

Domaine(s)
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

[...] débit d’équivalent de dose de rayonnement correspondant, déterminé au moyen d’un appareil approprié, par le calcul, ou, dans le cas des densités de flux de neutrons, par une conversion [...]

CONT

L’opérateur qualifié tente de réduire l’intensité de rayonnement en actionnant plusieurs fois la manivelle de la source de cobalt 60 [...]

CONT

Quiconque enlève une substance prescrite d’un dispositif d’exposition ou y insère une telle substance doit mesurer les niveaux de rayonnement et les doses d’exposition aux rayonnements pendant et immédiatement après l’enlèvement ou l’insertion de la substance prescrite, et soumettre les relevés au détenteur de permis.

Spanish

Campo(s) temático(s)
  • Física radiológica (Teoría y aplicación)
  • Compartimiento - Comisión Canadiense de Seguridad Nuclear
Key term(s)
  • grado de radiación
Save record 9

Record 10 2008-12-12

English

Subject field(s)
  • Scientific Measurements and Analyses
  • Atomic Physics
  • Nuclear Fission Reactors

French

Domaine(s)
  • Mesures et analyse (Sciences)
  • Physique atomique
  • Réacteurs nucléaires de fission
CONT

[Deux] techniques sont utilisables pour obtenir une estimation du taux de comptage moyen et donc du débit de fluence neutronique :-la méthode du carré de la tension moyenne [...] Grâce à un circuit quadrateur qui délivre une tension proportionnelle au carré de la tension d’entrée, le signal obtenu est alors proportionnel au niveau de puissance. C'est le principe du traitement analogique des fluctuations;-la méthode du calcul de la variance [...]

Spanish

Save record 10

Record 11 2008-12-12

English

Subject field(s)
  • Scientific Measurements and Analyses
  • Atomic Physics
  • Nuclear Fission Reactors

French

Domaine(s)
  • Mesures et analyse (Sciences)
  • Physique atomique
  • Réacteurs nucléaires de fission
CONT

[Deux] techniques sont utilisables pour obtenir une estimation du taux de comptage moyen et donc du débit de fluence neutronique :-la méthode du carré de la tension moyenne [...];-la méthode du calcul de la variance [qui] consiste à calculer en ligne la variance du signal sur la base d’un échantillonnage rapide. Les amplitudes sont numérisées et un processeur calcule directement la moyenne et la variance des échantillons ainsi obtenus. C'est le principe du traitement numérique des fluctuations.

Spanish

Save record 11

Record 12 2007-01-13

English

Subject field(s)
  • Computer Graphics
  • Telecommunications Transmission
  • Audiovisual Techniques and Equipment
  • Video Technology
CONT

The MPEG standard is primarily a bitstream specification, although it also specifies a typical decoding process to assist in interpreting the bitstream specification. This approach supports data interchange, but it does not restrict creativity and innovation in the means for creating or decoding that bitstream. The bitstream architecture is based on a sequence of pictures, each of which contains the data needed to create a single displayable image. Note that the order of transmission of pictures in the data stream may not be the same as the order in which pictures will be displayed - this will be evident shortly. There are four different kinds of pictures, depending on how each picture is to be decoded: I pictures ... P pictures ... B pictures are interpolated pictures, which are coded by interpolating between a previous and a future I or P picture. This process is sometimes referred to as "bidirectional prediction."

French

Domaine(s)
  • Infographie
  • Transmission (Télécommunications)
  • Audiovisuel (techniques et équipement)
  • Vidéotechnique
DEF

Image codée en utilisant une prédiction compensée du mouvement, d’après une image de référence antérieure et/ou future.

CONT

Le débit numérique d’images vidéo compressées selon MPEG-1 a été fixé à 1, 5 Mbits/s, compatible avec le taux de transfert des lecteurs de CD ROM, dans le but de développer des applications multimédia basées sur le stockage de séquences animées. Le format standard mais paramétrable des images est de 352 X 288 pixels, avec vidéo non entrelacée. [...] Trois statuts d’images ont donc été définis :-l'«intrapicture»,(image de type I) qui est transmise dans sa totalité selon une compression identique à JPEG. Elle servira de référence pour le calcul des autres images et lors des accès aléatoires dans une lecture accélérée de type magnétoscope(notion de «keyframe» dans Quicktime) ;-la «predicted picture»(image de type P), ou image prédite, codée à partir des images complètes précédentes grâce aux vecteurs de mouvements des blocs 8 X 8 pixels et avec une correction d’erreur sur le contenu du bloc, environ une image sur trois;-l'image interpolée ou bi-directionnelle(image de type B) [...]

OBS

Vidéo.

Spanish

Save record 12

Record 13 2001-01-09

English

Subject field(s)
  • Drainage and Irrigation (Agric.)
  • Irrigation (Civil Engineering)
CONT

The maximum allowable furrow flows are also the same, 1.768 m3/min. A rule-of-thumb states that the advance time for reuse systems should be about 30 percent of the required intake opportunity time. From Figure 56, the first irrigation flow should be .082 m3/min ...

French

Domaine(s)
  • Drainage et irrigation (Agriculture)
  • Irrigation (Génie civil)
DEF

Débit employé pour l’arrosage d’une étendue déterminée de terrain.

CONT

Le débit d’arrosage est le débit effectivement utilisé par l'irrigant. Il s’exprime en litre par seconde ou en mêtre cube par heure [...] Dans un périmètre d’irrigation collectif, le débit d’équipement est le débit d’arrosage, ramené à l'hectare, qui est prévu en moyenne pour le calcul du dimensionnement du réseau [...]

Spanish

Save record 13

Record 14 1999-02-26

English

Subject field(s)
  • Cooling and Ventilating Systems
CONT

Centrifugal fans are divided into four general classifications: Forward Curve (FC), Backward Inclined (BI), Radial Blade, and Tubular Centrifugal.

CONT

Backward curved and backward inclined blade fans. Backward curved and backward inclined blades are slightly less efficient, cost less, and generate slightly more noise than the airfoil type. The number of blades is usually ten to sixteen and the fan scroll is the same as for airfoil fans. Backward curved blades ... are constant thickness airfoil blades and are preferred over straight backward inclined blades ... because they allow smoother air flow and are stronger. Backward curved blade fans will operate over the full range of air flow from wide open to shut off, whereas backward inclined blade fans are unstable under flow condition below the design point. These fans are used in industrial applications in which fouling of the blades by airborne contaminants would minimize the efficiency advantage of airfoil blade fans.

OBS

"Backward curved blade fan" and "backward inclined blade fan" are usually synonyms, but some sources make a distinction between those two terms. In the "backward curved blade fan", the blade is curved, and in the "backward inclined blade fan", the blade is straight.

French

Domaine(s)
  • Systèmes de refroidissement et de ventilation
CONT

Ventilateurs à pales courbées et inclinées vers l'arrière. Les pales courbées et inclinées vers l'arrière sont un peu moins efficaces, coûtent moins cher et sont légèrement plus bruyantes que les pales à profil aérodynamique. Il y a habituellement dix à seize pales montées sur la roue et le carter spiralé est identique à celui d’un ventilateur à pales à profil aérodynamique. Les pales courbées vers l'arrière [...] constituent des pales à profil aérodynamique d’épaisseur constante et sont plus utilisées que les pales droites inclinées vers l'arrière [...] parce qu'elles génèrent un débit plus uniforme et sont plus durables. Les ventilateurs à pales courbées vers l'arrière fonctionnent sur toute la gamme de débits d’air, de la position complètement ouverte à la position complètement fermée, tandis que le fonctionnement des ventilateurs à pales inclinées vers l'arrière devient instable lorsque le débit est inférieur à la valeur du point de calcul. Lorsque ces ventilateurs à pales à profil aérodynamique sont utilisés dans l'industrie, l'encrassement des pales entraîné par des particules contaminées en suspension dans l'air réduit le rendement de ce type de ventilateurs.

OBS

Source de "ventilateur centrifuge à aubes inclinées vers l’arrière" : Giblin et Missenard, Cours supérieur de chauffage, ventilation et conditionnement d’air, Eyrolles, 1968, vol. 1, p. 69.

Spanish

Save record 14

Record 15 1996-12-04

English

Subject field(s)
  • Scientific Measurements and Analyses
  • Hydrology and Hydrography
DEF

Determination of the discharge of a stream by measuring the elemental areas between successive isovels and summing the products of each area by the mean of its boundary velocities.

French

Domaine(s)
  • Mesures et analyse (Sciences)
  • Hydrologie et hydrographie
DEF

Méthode de calcul du débit d’un cours d’eau consistant à mesurer les aires élémentaires comprises entre deux isotaches successives et à faire la somme du produit de chacune de ces aires par la moyenne de ses vitesses limites. Note : Une variante, utilisée de préférence en France, consiste en une double intégration graphique.

Spanish

Campo(s) temático(s)
  • Medición y análisis (Ciencias)
  • Hidrología e hidrografía
DEF

Determinación del caudal de un curso de agua mediante la medición de áreas entre isotacas sucesivas y la suma de los productos de cada área por la media de sus velocidades de contorno.

Save record 15

Record 16 1995-02-21

English

Subject field(s)
  • Computer Graphics
  • Telecommunications Transmission
  • Audiovisual Techniques and Equipment
  • Video Technology
CONT

The MPEG standard is primarily a bitstream specification, although it also specifies a typical decoding process to assist in interpreting the bitstream specification. This approach supports data interchange, but it does not restrict creativity and innovation in the means for creating or decoding that bitstream. The bitstream architecture is based on a sequence of pictures, each of which contains the data needed to create a single displayable image. Note that the order of transmission of pictures in the data stream may not be the same as the order in which pictures will be displayed - this will be evident shortly. There are four different kinds of pictures, depending on how each picture is to be decoded: I pictures are intracoded, meaning that they are coded independent of any other picture. An I picture must exist at the start of any video stream and also at any random-access entry point in the stream. P pictures.... B pictures.... D pictures....

French

Domaine(s)
  • Infographie
  • Transmission (Télécommunications)
  • Audiovisuel (techniques et équipement)
  • Vidéotechnique
DEF

Image codée en utilisant uniquement ses propres informations.

CONT

Le débit numérique d’images vidéo compressées selon MPEG-1 a été fixé à 1, 5 Mbits/s, compatible avec le taux de transfert des lecteurs de CD ROM, dans le but de développer des applications multimédia basées sur le stockage de séquences animées. Le format standard mais paramétrable des images est de 352 X 288 pixels, avec vidéo non entrelacée. [...] Trois statuts d’images ont donc été définis :-l'«intrapicture»,(image de type I) qui est transmise dans sa totalité selon une compression identique à JPEG. Elle servira de référence pour le calcul des autres images et lors des accès aléatoires dans une lecture accélérée de type magnétoscope(notion de «keyframe» dans Quicktime) ;-la «predicted picture»(image de type P), ou image prédite, codée à partir des images complètes précédentes grâce aux vecteurs de mouvements des blocs 8 x 8 pixels et avec une correction d’erreur sur le contenu du bloc, environ une image sur trois;-l'image interpolée ou bi-directionnelle(image de type B) [...]

OBS

Vidéo.

Spanish

Save record 16

Record 17 1995-02-21

English

Subject field(s)
  • Computer Graphics
  • Telecommunications Transmission
  • Audiovisual Techniques and Equipment
  • Video Technology
CONT

The MPEG standard is primarily a bitstream specification, although it also specifies a typical decoding process to assist in interpreting the bitstream specification. This approach supports data interchange, but it does not restrict creativity and innovation in the means for creating or decoding that bitstream. The bitstream architecture is based on a sequence of pictures, each of which contains the data needed to create a single displayable image. Note that the order of transmission of pictures in the data stream may not be the same as the order in which pictures will be displayed - this will be evident shortly. There are four different kinds of pictures, depending on how each picture is to be decoded: I pictures.... P pictures are predicted pictures, which are coded using motion compensation from a previous I or P picture. B pictures.... D pictures....

French

Domaine(s)
  • Infographie
  • Transmission (Télécommunications)
  • Audiovisuel (techniques et équipement)
  • Vidéotechnique
DEF

Image codée en utilisant une prédiction compensée en mouvement à partir de l’image de référence antérieure.

CONT

Le débit numérique d’images vidéo compressées selon MPEG-1 a été fixé à 1, 5 Mbits/s, compatible avec le taux de transfert des lecteurs de CD ROM, dans le but de développer des applications multimédia basées sur le stockage de séquences animées. Le format standard mais paramétrable des images est de 352 X 288 pixels, avec vidéo non entrelacée. [...] Trois statuts d’images ont donc été définis :-l'«intrapicture»,(image de type I) qui est transmise dans sa totalité selon une compression identique à JPEG. Elle servira de référence pour le calcul des autres images et lors des accès aléatoires dans une lecture accélérée de type magnétoscope(notion de «keyframe» dans Quicktime) ;-la «predicted picture»(image de type P), ou image prédite, codée à partir des images complètes précédentes grâce aux vecteurs de mouvements des blocs 8 X 8 pixels et avec une correction d’erreur sur le contenu du bloc, environ une image sur trois;-l'image interpolée ou bi-directionnelle(image de type B) [...]

OBS

Vidéo.

Spanish

Save record 17

Record 18 1994-09-16

English

Subject field(s)
  • Computer Graphics

French

Domaine(s)
  • Infographie
CONT

Le débit numérique d’images vidéo compressées selon MPEG-1 a été fixé à 1, 5 Mbits/s, compatible avec le taux de transfert des lecteurs de CD ROM, dans le but de développer des applications multimédia basées sur le stockage de séquences animées. Le format standard mais paramétrable des images est de 352 X 288 pixels, avec vidéo non entrelacée. Le principe de compression est le même que celui employé pour JPEG, à base de transformée par cosinus discrète(DCT en anglais), mais au lieu de compresser chaque image comme une entité unique, on transmet pour chaque bloc de 8 X 8 pixels les différences d’information avec le bloc correspondant de l'image précédente. Le codage est alors dit «inter-images»(ou «interframe» en anglais). Pour être encore plus efficace, l'algorithme MPEG emploie une technique de compensation de mouvement(«motion compensation») par laquelle une image prédictive est définie à partir des vecteurs de déplacement des blocs de 8 X 8 pixels évalués à partir des images précédentes. Même avec la technique de compensation de mouvement, le débit numérique obtenu est encore trop élevé. Trois statuts d’images ont donc été définis :-l'«intrapicture»,(image de type I) qui est transmise dans sa totalité selon une compression identique à JPEG. Elle servira de référence pour le calcul des autres images et lors des accès aléatoires dans une lecture accélérée de type magnétoscope(notion de «keyframe» dans Quicktime) ;-la «predicted picture»(image de type P) [...] l'image interpolée ou bi-directionnelle(image de type B) [...]

Spanish

Save record 18

Record 19 1992-06-29

English

Subject field(s)
  • Hydrology and Hydrography
  • Scientific Measurements and Analyses
DEF

A numerical technique of computing discharges in a tidal channel at a cross-section from the rates of change in volume of water up to the tidal limit, with algebraic allowance for the freshwater discharges entering the channel.

OBS

The maximum volume is usually that Occurring at high water of spring tide.

French

Domaine(s)
  • Hydrologie et hydrographie
  • Mesures et analyse (Sciences)
DEF

Technique numérique de calcul du débit dans une section d’un canal à marée, à partir des vitesses de variation du volume d’eau jusqu'à la limite où la marée ne se fait plus sentir, en tenant compte algébriquement du débit d’eau douce entrant dans le canal.

Spanish

Save record 19

Record 20 1985-08-12

English

Subject field(s)
  • HVAC Distribution Systems
CONT

When the heating, cooling, or ventilation load is established, the total flow rate of air required can be determined by methods shown in Chapters 21 and 22.

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
CONT

Canalisations. Ce calcul [besoins calorifiques des locaux] est relativement simple en ce qui concerne le débit d’air nécessaire.

Spanish

Save record 20

Record 21 1985-06-28

English

Subject field(s)
  • Electronics
  • Information Processing (Informatics)

French

Domaine(s)
  • Électronique
  • Traitement de l'information (Informatique)

Spanish

Save record 21

Record 22 1977-03-08

English

Subject field(s)
  • Environmental Studies and Analyses
  • Wastewater Treatment
DEF

The maximum rate of flow of wastewater to a pumping station or treatment plant.

French

Domaine(s)
  • Études et analyses environnementales
  • Traitement des eaux usées
CONT

Calcul du débit de pointe des réseaux d’égout. On part du débit moyen journalier Qm qu'on évalue en litres par seconde et on le multiplie par le coefficient de pointe p(...)

Spanish

Save record 22

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: