TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

COLLIMATEUR FAISCEAU [6 records]

Record 1 2014-06-19

English

Subject field(s)
  • Radiotherapy
  • Cancers and Oncology
CONT

Intensity-modulated radiation therapy (IMRT) is a new technology in radiation oncology that delivers radiation more precisely to the tumor while relatively sparing the surrounding normal tissues ... IMRT has wide application in most aspects of radiation oncology because of its ability to create multiple targets and multiple avoidance structures, to treat different targets simultaneously to different doses as well as to weight targets and avoidance structures according to their importance. By delivering radiation with greater precision, IMRT has been shown to minimize acute treatment-related morbidity, making dose escalation feasible which may ultimately improve local tumor control ...

French

Domaine(s)
  • Radiothérapie
  • Cancers et oncologie
CONT

Les progrès constants en radiothérapie ont tous pour but de focaliser les rayons le plus précisément possible sur la tumeur et d’épargner au maximum les tissus sains. C'est le cas de la technique de radiothérapie conformationnelle avec modulation d’intensité, forme spécialisée de radiothérapie conformationnelle dans laquelle on utilise des images scanner de la région à traiter associées à des logiciels spécifiques d’optimisation de la dose qui permettent de planifier l'irradiation de manière très ciblée. La radiothérapie conformationnelle avec modulation d’intensité consiste à faire varier la forme du faisceau et l'intensité du faisceau au cours d’une même séance pour s’adapter précisément au volume à traiter. On a recours à un dispositif spécial appelé collimateur multilames couplé à un accélérateur linéaire de particules.

Spanish

Save record 1

Record 2 2010-04-20

English

Subject field(s)
  • Radiography (Medicine)
  • Medical and Surgical Equipment
DEF

"collimator": In radiography, ... an adjustable beam delimiter attached to the x-ray tube housing the port. Two pairs of movable iron or lead shutters form a rectangular aperture through which the primary beam passes. All new diagnostic x-ray machines are required by federal regulations to have an automatic collimator, which limits the beam to the exact site of the film.

French

Domaine(s)
  • Radiographie (Médecine)
  • Équipement médico-chirurgical
DEF

«collimateur» : Appareil permettant d’obtenir un faisceau de rayons lumineux parallèles.

Spanish

Save record 2

Record 3 - external organization data 2003-07-02

English

Subject field(s)
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
DEF

A small radiation shield of lead or other heavy metal used in radiography.

CONT

A collimator which is placed on the end of the guide tube has a small opening through which a narrow cone of radiation escapes when the source is cranked into the collimator. Use of a collimator can greatly reduce the size of the controlled area to which access must be restricted.

CONT

Collimators are small pieces of lead, uranium, or tungsten that partially surround the source to absorb radiation not directed toward the object being radiographed. The small size of collimators makes them easily portable so they can be carried into the field.

French

Domaine(s)
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

Petit blindage utilisé en gammagraphie et fait de plomb ou de d’autres métaux lourds.

CONT

Le collimateur, placé à l'extrémité du tube de guidage, est muni d’une petite ouverture par laquelle passe un mince faisceau de rayonnement lorsque la source est sortie. L'utilisation du collimateur permet de réduire de beaucoup les dimensions de la zone où l'accès doit être limité.

CONT

Les collimateurs sont des petites pièces de plomb, d’uranium ou de tungstène disposées autour de la source pour absorber les rayonnements qui ne sont pas dirigés vers l’objet à gammagraphier. Parce qu’ils sont petits, les collimateurs sont faciles à transporter et à utiliser sur les lieux de travail.

Spanish

Save record 3

Record 4 2002-07-16

English

Subject field(s)
  • Metrology and Units of Measure
  • Astrophysics and Cosmography
  • Navigation Instruments
  • Flight Instruments and Equipment (Aeroindustry)
DEF

A unit of angular measure in which there are 360 arc degrees in a full circle.

CONT

If the gyroscope were a perfect instrument, it would be possible to determine the position of a satellite or a space vehicle with respect to its own fixed axes. But a gyroscope precesses... A very good gyroscope only precesses a few thousandths of a degree of arc in an hour, but at the end of a week the error is about one degree and it is twenty-five degrees at the end of six months.

OBS

One degree of arc is defined as equivalent to 60 minutes of arc (or "arc minutes"). Arc minutes are further divided into arc seconds, such that there are 60 x 60 or 3600 arc seconds per degree.

French

Domaine(s)
  • Unités de mesure et métrologie
  • Astrophysique et cosmographie
  • Instruments de navigation
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

parallaxe annuelle : Pour les étoiles lointaines, on utilise le demi-grand axe de l’orbite terrestre comme longueur de référence; on parle alors de parallaxe annuelle. La parallaxe annuelle w d’une étoile, exprimée en secondes de degrés d’arc, permet de déterminer la distance D de l’étoile en parsecs, d’après la relation approximative : D=1/w. parsec (n.m) : (de parallaxe et seconde) Un parsec représente la distance à la Terre d’un astre dont la parallaxe annuelle est égale à une seconde de degré d’arc.

CONT

Le collimateur [ISO] est basé sur une combinaison optique Newton avec un miroir primaire parabolique et un secondaire plan. Le faisceau est coudé et les sources sont positionnées sur le dessus du tube au moyen de mouvements linéaires XYZ. Le diamètre du miroir primaire est de 700 mm avec une ouverture de f/4. Le tube du collimateur est supporté par des mécanismes de translation motorisés qui permettent d’orienter l'axe optique à l'intérieur d’un cône de 2 arc degrés. Hauteur nominale de l'axe optique : 1400 mm. Ce collimateur a été développé pour permettre de tester les performances optiques de petits télescopes sortant de fabrication

Spanish

Save record 4

Record 5 - external organization data 1995-01-13

English

Subject field(s)
  • Radiation Protection
  • Compartment - Canadian Nuclear Safety Commission
CONT

... the use of supplementary shielding such as shield screens, lead blocks or sheeting and beam collimators.

French

Domaine(s)
  • Radioprotection
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

[...] l’utilisation de blindage supplémentaire, tels les écrans de blindage, les blocs ou les revêtements de plomb, ainsi que les collimateurs de faisceau.

Spanish

Save record 5

Record 6 1989-11-16

English

Subject field(s)
  • Optical Instruments
  • Chemistry
  • Analytical Chemistry
DEF

A device, allied to the electron microscope, in which a beam of electrons strikes the sample, showing crystal pattern and other physical attributes on the resulting diffraction pattern; used for chemical analysis, atomic structure determination, and so on.

French

Domaine(s)
  • Instruments d'optique
  • Chimie
  • Chimie analytique
CONT

Les études de structures au moyen d’électrons accélérés par des potentiels de l'ordre de 50 kV utilisent des appareils appelés diffractographes électroniques qui ont de nombreux points communs avec les microscopes électroniques ordinaires. Le principe en est le suivant : un faisceau d’électrons émis par exemple par un filament de tungstène, dans une enceinte où règne un vide poussé, est canalisé par un collimateur(...) et accéléré par une tension variant entre 30 et 100 kV. Les échantillons sont examinés soit par transmission(ils doivent alors être sous forme de films très minces), soit par réflexion(étude de couches superficielles). L'observation se fait sur écran fluorescent; l'enregistrement, sur plaques photographiques. La diffraction des électrons permet par exemple d’étudier un échantillon constitué de deux ou plusieurs phases distinctes; on obtient des diagrammes de diffraction présentant des taches différentes(...)

Spanish

Save record 6

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: