TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

FUITE SURFACE [24 records]

Record 1 2017-06-07

English

Subject field(s)
  • Optics
  • Magnetic Materials and Ferromagnetism
  • Destructive and Non-destructive Tests (Mat.)
CONT

Two types of wet magnetic particles may be used ... [in the wet magnetic particle inspection] (1) Fluorescent Magnetic Particles. The particles used in the wet method fluorescent magnetic particle both are coated with a dye which causes them to fluoresce brilliantly when exposed to near ultraviolet (black) light ... (2) Visible Magnetic Particles. The visible magnetic particles normally used in the wet baths are either reddish or black and are observed under normal white light.

French

Domaine(s)
  • Optique
  • Matériaux magnétiques et ferromagnétisme
  • Contrôle destructif et non destructif (Matér.)
CONT

Inspection par particules magnétiques [...] Après avoir magnétisé le tube, on projette à sa surface de fines particules ferromagnétiques. Celles-ci sont attirées et accumulées par les champs de fuite qui se comportent à leur égard comme de minuscules aimants. Ces accumulations visibles de particules matérialisent donc les défauts en constituant ce que l'on appelle «les spectres des défauts». [...] Les particules projetées à la surface du tube sont de la poudre de fer ou d’oxyde de fer et peuvent être classées en deux familles : les révélateurs pour application par voie humide; les révélateurs pour application par voie sèche. a) Les révélateurs liquides [...] sont les plus satisfaisants pour la détection des défauts fins de surface. Les particules ferromagnétiques de couleur noire, jaune, rouge ou fluorescente sont en suspension dans un produit pétrolier.

OBS

[...] dans les procédés à la liqueur magnétique [...] la surface [de la pièce] est préparée par usinage ou par application de peinture, de manière à être suffisamment lisse pour ne pas gêner la distribution des particules magnétiques en suspension dans la liqueur et, autant que possible, à offrir un bon contraste avec la couleur de ces particules.

OBS

Les poudres utilisées pour préparer les liqueurs magnétiques [...] sont de couleur naturelle sombre [...] Toutefois, le diamètre réduit des grains les rend aptes à recevoir des enrobages variés ce qui donne des poudres colorées (en blanc, jaune, vert ...), voire fluorescentes en lumière noire.

OBS

«particule magnétique à enrobage fluorescent» : Lorsqu’on utilise une poudre magnétique à enrobage fluorescent, l’observation des spectres se fait en lumière noire dans un local sombre, ou dans une enceinte limitée par des rideaux noirs, après une période convenable d’accommodation de l’œil à l’obscurité.

Spanish

Save record 1

Record 2 2016-11-17

English

Subject field(s)
  • Insulators and Supporting Materials (Electr.)
  • Plastics Manufacturing
DEF

The formation of a conducting path across the surface of an insulating material by current discharge or leakage.

OBS

tracking: term and definition standardized by ISO.

French

Domaine(s)
  • Isolateurs et supports (Électricité)
  • Plasturgie
DEF

Formation d’une trace conductrice à la surface d’une matière isolante, par décharge électrique ou faible courant de fuite.

OBS

cheminement : terme et définition normalisés par l’ISO.

Spanish

Campo(s) temático(s)
  • Aisladores y soportes (Electricidad)
  • Fabricación de plásticos
DEF

Formación de una vía conductora a través de la superficie de un material aislante por descarga eléctrica o corriente de fuga.

Save record 2

Record 3 2015-04-09

English

Subject field(s)
  • Iron
CONT

The magnetic particle method is the most satisfactory method for finding surface and sub-surface defects. ... The basic principle of the method is that while magnetic flux lines are caused to flow in a part, the local disturbance at a flaw is detected by using a magnetic powder either dry, or preferably, as a suspension in a liquid. Ferroso-ferric oxide (magnetic oxide of iron, Fe3 04 is generally preferred to powdered soft iron although even iron filings will indicate the larger faults.

French

Domaine(s)
  • Fer
CONT

En projetant à la surface d’une pièce défectueuse de fines particules magnétiques, celles-ci sont attirées et accumulées par le champ de fuite qui se comporte à leur égard comme un minuscule aimant. Cette accumulation visible des particules donne ce que l'on nomme le "spectre du défaut". Ces particules sont généralement des oxydes magnétiques, plus rarement de la poudre de fer.

Spanish

Save record 3

Record 4 2015-04-09

English

Subject field(s)
  • Ferrous Alloys
  • Destructive and Non-destructive Tests (Mat.)
  • Inspection for Defects (Materials Engineering)
DEF

A nondestructive method for detecting cracks and other discontinuities at or near the surface in ferromagnetic materials. Finely divided magnetic particles are applied to the surface of a part which has been suitably magnetized. The particles are attracted to regions of magnetic nonuniformity associated with defects and discontinuities, thus producing indications which are observed visually....

OBS

Abbreviation officialized by the ATSC - Helicopters.

Key term(s)
  • magnetic particle examination

French

Domaine(s)
  • Alliages ferreux
  • Contrôle destructif et non destructif (Matér.)
  • Détection des défauts des matériaux
CONT

Le contrôle magnétoscopique s’applique exclusivement aux pièces en alliage ferromagnétique. Dans une telle pièce, supposée aimantée, une solution de continuité [...] crée une fuite magnétique. Par la suite de la réfraction magnétique, [...] les lignes d’induction sortent de la pièce [...] et dessinent dans l'atmosphère environnante un champ à forte courbure. Des particules ferromagnétiques [...] remontent les lignes d’induction pour se plaquer à la surface, où elles dessinent par leur accumulation un spectre élargi de la solution de continuité : l'élargissement apparent est d’autant plus important que la perturbation du champ est plus intense c'est-à-dire que le défaut qui la crée est de section relative plus forte(en fait plus étendu en profondeur).

OBS

contrôle par magnétisation : La désignation Contrôle magnétoscopique a été conservée par souci d’homogénéité avec le titre Épreuves magnétoscopiques de la norme NF A 04-101. Cependant, depuis quelques années, on voit se marquer une certaine préférence pour la désignation Contrôle par magnétisation, qui serait en meilleur parallélisme avec Contrôle par ressuage [...]

OBS

épreuve magnétoscopique : La désignation Contrôle magnétoscopique a été conservée par souci d’homogénéité avec le titre Épreuves magnétoscopiques de la norme NF A 04-101.

Spanish

Save record 4

Record 5 2015-04-09

English

Subject field(s)
  • Magnetic Materials and Ferromagnetism
  • Destructive and Non-destructive Tests (Mat.)
  • Inspection for Defects (Materials Engineering)
CONT

Magnetic particle testing is used for detecting surface and subsurface flaws in ferromagnetic materials ... The test is generally conducted by magnetizing the part to be inspected ... If finely divided ferromagnetic particles are applied in the vicinity of the crack, the particles will be attracted by the magnetic flux between the two poles. The visible accumulation produces a readily discernible indication on the surface of the test part.

OBS

ferromagnetic: Of or relating to a class of substances characterized by abnormally high magnetic permeability, definite saturation point and appreciable residual magnetism and hysteresis.

French

Domaine(s)
  • Matériaux magnétiques et ferromagnétisme
  • Contrôle destructif et non destructif (Matér.)
  • Détection des défauts des matériaux
CONT

Le contrôle magnétoscopique s’applique exclusivement aux pièces en alliage ferromagnétique [...] Dans une telle pièce [...] une solution de continuité [...] crée une fuite magnétique. Par suite de la réfraction magnétique [...] les lignes d’induction sortent de la pièce [...] à sa surface et dessinent dans l'atmosphère environnante un champ à forte courbure. Des particules ferromagnétiques [...] remontent les lignes d’induction pour se plaquer sur la surface, où elles dessinent par leur accumulation un spectre élargi de la solution de continuité [...]

OBS

ferromagnétique : Qualifie les corps (fer, fonte, acier et certains alliages) qui conservent une partie plus ou moins importante de leur aimantation lorsqu’on supprime l’influence du champ magnétisant.

Spanish

Save record 5

Record 6 2015-02-11

English

Subject field(s)
  • Oil and Natural Gas Extraction
CONT

This contiguous block of land is centred on a capped gas well 7-12-77-25 W6 which tested gas at commercial rates from the Falher zone. Gas reserves of 5.1 BCF were assigned to this well.

OBS

capping: The process of sealing a well to prevent oil or gas from leaking out.

French

Domaine(s)
  • Extraction du pétrole et du gaz naturel
OBS

puits de gaz obturé : Source : Discours de M. Howe, Hansard, 14 mai 1956, p. 3860-4003

OBS

coiffage : Procédé consistant à encapuchonner un puits en surface pour arrêter une fuite de pétrole ou de gaz.

Spanish

Save record 6

Record 7 2012-05-28

English

Subject field(s)
  • Inspection for Defects (Materials Engineering)
DEF

That which marks or denotes the presence of a discontinuity.

CONT

The particles are attracted to regions of magnetic nonuniformity associated with defects and discontinuities thus producing indications which are observed visually.

OBS

In magnetic particle inspection, it is the detectable magnetic particle buildup resulting from interruption of the magnetic field.

OBS

In liquid penetrant inspection, it is the presence of detectable bleedout of liquid penetrant from the material discontinuities.

French

Domaine(s)
  • Détection des défauts des matériaux
CONT

Le contrôle magnétoscopique s’applique exclusivement aux pièces en alliage ferromagnétique. Dans une telle pièce, supposée aimantée, une solution de continuité [...] crée une fuite magnétique. Par suite de la réfraction magnétique [...] les lignes d’induction sortent de la pièce [...] et dessinent [...] un champ à forte courbure. Des particules ferromagnétiques, abandonnées à elles-mêmes dans un tel champ, remontent en lignes d’induction pour se plaquer à la surface, où elles dessinent par leur accumulation un spectre élargi de la solution de continuité : l'élargissement est d’autant plus important que [...] le défaut qui [...] crée [la perturbation du champ] est [...] plus étendu en profondeur. Inversement, toute réduction de la perturbation diminue la visibilité du spectre.

Spanish

Save record 7

Record 8 2010-12-09

English

Subject field(s)
  • Measuring Instruments
  • Radiological Physics (Theory and Application)
CONT

The planar detector consists of a crystal of either rectangular or circular cross section and a sensitive thickness of 1-20 mm ... The electric field is perpendicular to the cross-sectional area of the crystal. The crystal thickness is selected on the basis of the gamma-ray energy region relevant to the application of interest, with the small thicknesses optimum for low-energy measurements (for example in the L-x-ray region for special nuclear material). Planar detectors usually achieve the best energy resolution, because of their low capacitance; they are preferred for detailed spectroscopy, such as the analysis of the complex low-energy gamma-ray and x-ray spectra of uranium and plutonium.

OBS

Solid-state detectors are produced mainly in two configurations: planar and coaxial. These terms refer to the detector crystal shape and the manner in which it is wired into the detector circuit.

French

Domaine(s)
  • Appareils de mesure
  • Physique radiologique et applications
OBS

Détecteurs réalisés selon la technique d’implantation ionique «planaire». La technologie de fabrication des détecteurs [au] silicium a beaucoup évolué au cours du dernier demi-siècle grâce aux progrès de la microélectronique. Aujourd’hui, on utilise le procédé d’implantation passivée planaire(ou Implantation Planar Process) qui a complètement supplanté les techniques de fabrication des détecteurs à barrière de surface ou à jonction diffusée. La technique actuelle basée sur l'utilisation d’implanteurs(accélérateurs d’ions de faible énergie), permet de réaliser des jonctions abruptes et minces grâce à un contrôle très précis de la position en profondeur des dopants(B pour type P et As pour type N) à l'intérieur d’un substrat de Si(réduction de la zone morte du dispositif) de haute résistivité(de type N–). Celui-ci est recouvert d’une couche mince de passivation(SiO2) afin de minimiser les courants de fuite de surface. Un traitement chimique par photolithographie permet de définir la géométrie finale du détecteur.

Spanish

Save record 8

Record 9 2010-12-07

English

Subject field(s)
  • Semiconductors (Electronics)
  • Radiological Physics (Theory and Application)
DEF

A low-energy ion accelerator process used to build a planar device such as a detector.

Key term(s)
  • planar ion implantation technique
  • planar ion-implantation process
  • planar ion-implantation

French

Domaine(s)
  • Semi-conducteurs (Électronique)
  • Physique radiologique et applications
CONT

Détecteurs réalisés selon la technique d’implantation ionique «planaire». La technologie de fabrication des détecteurs silicium a beaucoup évolué au cours du dernier demi-siècle grâce aux progrès de la microélectronique. Aujourd’hui, on utilise le procédé d’implantation passivée planaire […] qui a complètement supplanté les techniques de fabrication des détecteurs à barrière de surface ou à jonction diffusée. La technique actuelle basée sur l'utilisation d’implanteurs(accélérateurs d’ions de faible énergie), permet de réaliser des jonctions abruptes et minces grâce à un contrôle très précis de la position en profondeur des dopants(B pour type P et As pour type N) à l'intérieur d’un substrat de Si(réduction de la zone morte du dispositif) de haute résistivité(de type N–). Celui-ci est recouvert d’une couche mince de passivation(SiO2) afin de minimiser les courants de fuite de surface. Un traitement chimique par photolithographie permet de définir la géométrie finale du détecteur.

Spanish

Save record 9

Record 10 2006-05-27

English

Subject field(s)
  • Aerodynamics and Theory of Gases
  • Electric Rotary Machines - Types
  • Wind Energy
DEF

The point along the chord line of an airfoil one-quarter of the chord length from the leading edge.

CONT

The quarter chord point is located 25% of the distance from the leading edge to the trailing edge along the chord line, which is the straight line between the farthest forward and farthest aft points on the airfoil section.

French

Domaine(s)
  • Théorie des gaz et aérodynamique
  • Machines tournantes électriques - types
  • Énergie éolienne
DEF

Point situé au quart de la longueur de corde, du bord d’attaque au bord de fuite le long de la ligne de la corde de profil, laquelle est la droite délimitant les points extrêmes avant et arrière de la surface portante d’une pale.

Spanish

Save record 10

Record 11 2003-06-02

English

Subject field(s)
  • Magnetic Materials and Ferromagnetism
  • Destructive and Non-destructive Tests (Mat.)
  • Inspection for Defects (Materials Engineering)
  • Biotechnology
CONT

Magnetic particles are available as dry powder which are dusted or brushed onto the surface to be tested, and as magnetic paste for use in either oil or water suspension ... Magnetic particle patterns outline discontinuities and make them visible to the inspector.

French

Domaine(s)
  • Matériaux magnétiques et ferromagnétisme
  • Contrôle destructif et non destructif (Matér.)
  • Détection des défauts des matériaux
  • Biotechnologie
CONT

En projetant à la surface de la pièce défectueuse de fines particules magnétiques, celles-ci sont attirées et accumulées par le champ de fuite [...] Ces particules sont généralement des oxydes magnétiques, plus rarement de la poudre de fer [...] Ces particules magnétiques sont dans de rares cas projetées par voie sèche [...], le plus souvent elles sont [...] appliquées par arrosage.

Spanish

Campo(s) temático(s)
  • Materiales magnéticos y ferromagnetismo
  • Pruebas destructivas y no destructivas (Materiales)
  • Detección de fallas de los materiales
  • Biotecnología
Save record 11

Record 12 2003-04-16

English

Subject field(s)
  • Building Insulation and Acoustical Design
  • Thermal Insulation
DEF

The total area of all the gaps and holes in the sheating assembly of the panels.

French

Domaine(s)
  • Isolation et acoustique architecturale
  • Isolation thermique
DEF

Surface équivalant à l’ensemble des ouvertures ou des trous (dans les cadres de fenêtres, des portes, le toit, etc.) par où peuvent se produire des fuites d’air dans un bâtiment.

OBS

Traduction Normes et Construction.

Spanish

Campo(s) temático(s)
  • Aislamiento y acústica arquitectónicos
  • Aislamiento térmico
DEF

Estimado del área total de todos las aberturas no intencionales el la envoltura de un edificio, generalmente expresado en en centímetros cuadrados o pulgadas cuadradas.

Save record 12

Record 13 - external organization data 2002-02-18

English

Subject field(s)
  • Transport of Goods
  • Radioactive Contamination
  • Compartment - Canadian Nuclear Safety Commission
CONT

... the freight container conforms to the requirements prescribed in the International Organization for Standardization document ISO 1496/1-1978 ... when it is subjected to the tests prescribed in that document and the accelerations occurring during routine conditions of transport, it prevents: (i) loss or dispersal of the radioactive contents; and (ii) loss of shielding that results in more than a 20% increase in the radiation level on any of its external surfaces.

OBS

Regulation cited: Packaging and Transport of Nuclear Substances Regulations.

French

Domaine(s)
  • Transport de marchandises
  • Pollution par radioactivité
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

[...] le conteneur est conforme à la norme 1496/1-1978 de l'Organisation internationale de normalisation [...] et il empêche, lors des épreuves prévues dans cette norme et des accélérations dans des conditions normales de transport :(i) toute fuite ou dispersion du contenu radioactif,(ii) toute perte du blindage qui entraînerait une augmentation de plus de 20 % de l'intensité de rayonnement émanant de toute surface externe du conteneur.

OBS

Règlement cité : Règlement sur l’emballage et le transport des substances nucléaires.

Spanish

Save record 13

Record 14 2001-03-15

English

Subject field(s)
  • Printed Circuits and Microelectronics
  • Measurements of Electricity
DEF

The passage of current over the boundary surface of an insulator as distinguished from passage through its volume.

French

Domaine(s)
  • Circuits imprimés et micro-électronique
  • Mesures de grandeurs électriques
CONT

De part leur hydrophobie naturelle, les silicones EVC et RTV-2 remplacent avantageusement la porcelaine pour éviter les courants de fuite en surface sur les isolateurs de lignes haute tension.

Spanish

Save record 14

Record 15 2001-01-17

English

Subject field(s)
  • Oil and Natural Gas Extraction

French

Domaine(s)
  • Extraction du pétrole et du gaz naturel
OBS

coiffage : Procédé consistant à encapuchonner un puits en surface pour arrêter une fuite de pétrole ou de gaz.

Spanish

Save record 15

Record 16 2000-01-31

English

Subject field(s)
  • Water Distribution (Water Supply)
  • Plumbing
  • Public Utilities (Civil Engineering)
  • Urban Furnishings and Equipment
CONT

Urban Infrastructure Rehabilitation Program. Leak detection methods for plastic water distribution pipes... In many water distribution systems a significant percentage of water is lost while in transit from treatment plants to consumers... Econonic pressure, concern over public health risk and simply the need to conserve water motivate water system operators to implement leakage control programs. There are two major steps in any systematic leakage control program: (i) water audits, and (ii) leak detection surveys.

French

Domaine(s)
  • Distribution de l'eau
  • Plomberie
  • Services d'utilité publique (Génie civil)
  • Équipements urbains
CONT

Détection des fuites d’eau. La détection des fuites est par conséquent primordiale. Elles se situent à 80% au niveau des connexions, «points faibles» des réseaux. Des campagnes de détection sont constamment menées. Lyonnaise des Eaux utilise pour ce faire toute une batterie de technique : Le triphone, appareil d’écoute qui permet de détecter une fuite sur une canalisation. Le corrélateur acoustique qui localise précisément les fuites en analysant les variations sonores à l'intérieur de la canalisation. En zone rurale, un survol en avion avec une caméra à infrarouge permet de repérer les différences de température entre l'eau et le sol et donc de localiser les fuites. À Paris, où les réseaux de distribution d’eau sont installés dans les galeries techniques du réseau d’assainissement, les fuites ne peuvent être observées depuis la surface.

Spanish

Save record 16

Record 17 1997-12-17

English

Subject field(s)
  • Plastics Manufacturing
CONT

Several [internal cooling] systems have been developed that incorporate three basic approaches: liquified gas, super-cold air with water vapor, and air exchange methods. ... The air-exchange system is a far simpler method. Here, after the parison has been expanded, plant air is allowed to circulate through the bottle and exhaust. Differential pressure inside the bottle is maintained at 80 psi (550 kPa) to ensure that the parison stays in contact with the mold cavity. Production rate improvements are modest; only 10-15% improvement can be expected.

Key term(s)
  • air exchange system

French

Domaine(s)
  • Plasturgie
CONT

Le temps de refroidissement devient pratiquement proportionnel au carré de l'épaisseur, c'est pourquoi on a songé à compléter le refroidissement par contact avec l'empreinte par un refroidissement interne selon les différents procédés décrits ci-après. a) Renouvellement de l'air de soufflage. On crée une fuite d’air, ce qui permet d’assurer un certain balayage interne permettant d’évacuer une partie de la chaleur, ce qui conduit à une diminution du temps de refroidissement de l'ordre de 5%. b) Balayage au dioxyde de carbone. [...] c) Procédé ISC(Internal Surface Cooling). [...] d) Procédé ALEX. [...]

OBS

Refroidissement par l’intérieur. L’évacuation des calories peut se faire par une circulation de l’air de soufflage. Pour ceci, la canne de soufflage comporte une entrée et une sortie de l’air.

Spanish

Save record 17

Record 18 1996-10-09

English

Subject field(s)
  • Magnetism
  • Destructive and Non-destructive Tests (Mat.)
  • Inspection for Defects (Materials Engineering)
DEF

The accumulation of ferromagnetic particles along the areas of flaws or discontinuities due to the distortion of the magnetic lines of force in those areas.

French

Domaine(s)
  • Magnétisme
  • Contrôle destructif et non destructif (Matér.)
  • Détection des défauts des matériaux
CONT

En projetant à la surface d’une pièce défectueuse de fines particules magnétiques, celles-ci sont attirées et accumulées par le champ de fuite qui se comporte à leur égard comme un minuscule aimant. Cette accumulation visible des particules donne ce que l'on nomme le "spectre du défaut".

Spanish

Save record 18

Record 19 1996-09-25

English

Subject field(s)
  • Magnetism
  • Metallography
DEF

The magnetic field which leaves or enters the surface of a part at a discontinuity or change in section configuration of a magnetic circuit.

French

Domaine(s)
  • Magnétisme
  • Métallographie
CONT

Si(...) on fait parcourir une pièce par les lignes de force d’un champ magnétique, et que ces lignes de force rencontrent un défaut, c'est-à-dire une zone plus réluctante, elles ne vont pas le traverser, mais le contourner. Cette perturbation se communiquera aux lignes de force adjacentes, et se propagera jusqu'aux lignes proches de la surface de la pièce. Ces dernières, "bousculées" à leur tour et ne trouvant plus de place pour cheminer au travers du métal, vont "fuir" à l'extérieur, créant un champ local dénommé pour cette raison, "champ de fuite", au droit du défaut(...)

Spanish

Save record 19

Record 20 1995-12-22

English

Subject field(s)
  • Testing and Quality Control (Packaging)
CONT

Stacking test.... Method of testing. Packages must be capable of withstanding for a period of 24 hours a superimposed weight placed on a flat surface resting on the top of the package and equivalent to the total weight of identical packages which could be stacked on it during transport. The minimum stacking height must be 3 m.... Criteria for passing the test successfully. There must be no serious rupture of any of the tested drums nor any rupture or leakage of the inner receptacles they may contain. The drum must not show any deformation likely to reduce its strength or to cause instability in stacks.

French

Domaine(s)
  • Essais et contrôle (Emballages)
CONT

Épreuve de gerbage. [...] Manière de procéder à l'épreuve. Chaque colis doit pouvoir supporter pendant une période de 24 heures un poids superposé appliqué sur une surface plane reposant sur son sommet et équivalent au poids total des colis identiques qui pourraient être gerbés au-dessus de lui durant le transport. En général, la hauteur de gerbage minimale doit être de 3 m. [...] Critères à utiliser pour déterminer si l'épreuve a été subie de manière satisfaisante. Il ne doit y avoir ni rupture importante des fûts ayant subi les épreuves, ni rupture ou fuite des récipients intérieurs qu'ils peuvent contenir. Le fût ne doit pas laisser apparaître de déformation susceptible de réduire sa solidité ou d’entraîner un manque de stabilité lorsque les fûts sont empilés.

Spanish

Save record 20

Record 21 1993-07-09

English

Subject field(s)
  • Waste Management
  • Nuclear Waste Materials
CONT

Wastes containing significant concentrations of radioactivity now are stored in bunkers at Chalk River either at or near the surface. The bunkers are continually monitored to ensure that there is no leakage of radioactivity and that non one inadvertently ventures onto the site.

French

Domaine(s)
  • Gestion des déchets
  • Déchets nucléaires
CONT

Les déchets comprenant d’importantes concentrations de matières radioactives sont actuellement entreposés dans des casemates à Chalk River, en surface ou à faible profondeur. On surveille en permanence ces casemates de manière à déceler toute fuite de matières radioactives, et à s’assurer que personne ne s’aventure sur le site.

Spanish

Save record 21

Record 22 1993-07-09

English

Subject field(s)
  • Waste Management
  • Nuclear Waste Materials
CONT

Wastes containing significant concentrations of radioactivity now are stored in bunkers at Chalk River either at or near the surface. The bunkers are continually monitored to ensure that there is no leakage of radioactivity and that non one inadvertently ventures onto the site.

OBS

See also "near-surface disposal".

French

Domaine(s)
  • Gestion des déchets
  • Déchets nucléaires
CONT

Les déchets comprenant d’importantes concentrations de matières radioactives sont actuellement entreposés dans des casemates à Chalk River, en surface ou à faible profondeur. On surveille en permanence ces casemates de manière à déceler toute fuite de matières radioactives, et à s’assurer que personne ne s’aventure sur le site.

Spanish

Save record 22

Record 23 1988-04-30

English

Subject field(s)
  • Oil Production
  • Heat (Physics)
CONT

Wellbore heat loss. Unless a heat injection well is properly designed, considerable amonts of heat can be lost from the injected fluid as it travels down the wellbore.

French

Domaine(s)
  • Production pétrolière
  • Chaleur (Physique)
OBS

Une autre cause de fuite thermique est la circulation des fluides chauds dans les puits d’injection depuis la surface jusqu'à la couche à exploiter.

Spanish

Save record 23

Record 24 1986-05-09

English

Subject field(s)
  • Civil Engineering
  • Water Treatment (Water Supply)

French

Domaine(s)
  • Génie civil
  • Traitement des eaux
DEF

Modification locale de la surface d’un filtre entraînant une fuite d’eau importante et diminuant l'efficacité de la filtration.

Spanish

Save record 24

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: