MICROSCOPIE CONFOCALE BALAYAGE LASER [2 records]

Record 1 2003-07-17

English

Subject field(s)
  • Optics
  • Scientific Measurements and Analyses
DEF

A laser scanning microscopy system that focuses on a single plane of light through a biological substance, allowing high-resolution, three-dimensional images to be built up.

CONT

Laser Scanning Confocal Microscopy (LSCM, also referred to as CSLM, Confocal Scanning Laser Microscopy) is now established as a valuable tool for obtaining high resolution images and 3-D reconstructions of a variety of biological specimens. In LSCM, a laser light beam is expanded to make optimal use of the optics in the objective. Through a x-y deflection mechanism this beam is turned into a scanning beam, focussed to a small spot by an objective lens onto a fluorescent specimen. The mixture of reflected light and emitted fluorescent light is captured by the same objective and (after conversion into a static beam by the x-y scanner device) is focused onto a photodetector (photomultiplier) via a dichroic mirror (beam splitter). The reflected light is deviated by the dichroic mirror while the emitted fluorescent light passes through in the direction of the photomultiplier. A confocal aperture (pinhole) is placed in front of the photodetector, such that the fluorescent light (not the reflected light!) from points on the specimen that are not within the focal plane (the so called out-of-focus light) where the laser beam was focussed will be largly obstructed by the pinhole. In this way, out-of-focus information (both above and below the focal plane) is greatly reduced.

French

Domaine(s)
  • Optique
  • Mesures et analyse (Sciences)
CONT

Principe de la microscopie confocale à balayage laser (MCBL). Le rayon laser excitateur pénètre dans l'échantillon préalablement marqué par des fluorochromes [...], auparavant répertoriés et choisis en fonction de leurs propriétés à se fixer sur des molécules particulières d'une structure ou d'un objet d'intérêt. Lors de l'impact optique, il y a émission de rayons lumineux provenant de différents plans de la préparation. Grâce à un diaphragme variable («trou d'aiguille» - pinhole), il est possible de sélectionner les rayons émis par un seul plan de préparation et d'éliminer le signal provenant d'autres plans. Les rayons réfléchis sont filtrés en fonction de leur longueurs d'onde puis détectés par des photo-multiplicateurs. Le signal reçu est enfin converti en signal numérique, contribuant à la création d'une image [...]

OBS

Tous les champs d'application de la microscopie confocale à balayage laser : localisations intracellulaires par fluorescence (simple et double marquage), reconstitution 3D par fluorescence de structures cellulaires, hybridation in situ, cinétique de processus dans les cellules vivantes, états de surface de matériaux divers.

Spanish

Save record 1

Record 2 2003-05-29

English

Subject field(s)
  • Optics
  • Chemistry
CONT

Confocal laser scanning microscopy with 1-photon excitation ... became a practical technique with the introduction of the first commercially available models in the early 1980's. Laser scanning microscopes (LSM) with 2-photon excitation (2P-LSM) have been commercially available since 1997.

CONT

Conventional one-photon confocal laser scanning microscopy (CLSM) often provides high resolution but is limited in sensitivity and spatial resolution by background flare noise resulting from "out-of-focus" fluorescence.

Key term(s)
  • 1-photon CLSM
  • 1-photon confocal laser scanning microscopy

French

Domaine(s)
  • Optique
  • Chimie
OBS

La première fonction de l'excitation laser est d'arracher un électron à l'agrégat. En effet, la séparation en masse des espèces neutres, nécessaire à toute étude d'agrégats, ne peut se faire que si l'agrégat est ionisé. Ceci peut se faire de diverses manières: excitation à un photon, excitation à deux photons résonnante (R2PI) ou non, dépendant du type d'agrégats et de l'expérience réalisée.

OBS

Nous discuterons [...] des divers avantages de la technique biphotonique par rapport à son homologue en excitation monophotonique : le microscope confocal de fluorescence. Dans une deuxième partie, nous décrirons brièvement les différentes techniques d'imagerie à haute résolution spatiale de la fluorescence utilisées en microscopie confocale ou biphotonique de fluorescence et nous introduirons le principe des deux techniques d'analyse dynamique de l'émission de la fluorescence que nous avons développées dans le cadre de notre projet : la microscopie de corrélation de fluorescence et l'imagerie de temps de vie de fluorescence.

Spanish

Save record 2

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: